Abstract Background and objective Automatic voice condition analysis systems to detect Parkinson’s disease (PD) are generally based on speech data recorded under acoustically controlled conditions and professional supervision. The performance of these approaches in a free-living scenario is unknown. The aim of this research is to investigate the impact of uncontrolled conditions (realistic acoustic environment and lack of supervision) on the performance of automatic PD detection systems based on speech. Methods A mobile-assisted voice condition analysis system is proposed to aid in the detection of PD using speech. The system is based on a server–client architecture. In the server, feature extraction and machine learning algorithms are designed and implemented to discriminate subjects with PD from healthy ones. The Android app allows patients to submit phonations and physicians to check the complete record of every patient. Six different machine learning classifiers are applied to compare their performance on two different speech databases. One of them is an in-house database (UEX database), collected under professional supervision by using the same Android-based smartphone in the same room, whereas the other one is an age, sex and health-status balanced subset of mPower study for PD, which provides real-world data. By applying identical methodology, single-database experiments have been performed on each database, and also cross-database tests. Cross-validation has been applied to assess generalization performance and hypothesis tests have been used to report statistically significant differences. Results In the single-database experiments, a best accuracy rate of 0.92 (AUC = 0.98) has been obtained on UEX database, while a considerably lower best accuracy rate of 0.71 (AUC = 0.76) has been achieved using the mPower-based database. The cross-database tests provided very degraded accuracy metrics. Conclusion The results clearly show the potential of the proposed system as an aid for general practitioners to conduct triage or an additional tool for neurologists to perform diagnosis. However, due to the performance degradation observed using data from mPower study, semi-controlled conditions are encouraged, i.e., voices recorded at home by the patients themselves following a strict recording protocol and control of the information about patients by the medical doctor at charge.

Funder

Agencia Estatal de Investigación

Consejería de Educación y Empleo, Junta de Extremadura

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Biomedical Engineering,General Medicine,Biomaterials,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3