Author:
Lin Anthony Y.,Varghese Chris,Du Peng,Wells Cameron I.,Paskaranandavadivel Niranchan,Gharibans Armen A.,Erickson Jonathan C.,Bissett Ian P.,O’Grady Greg
Abstract
Abstract
Background
Cyclic motor patterns (CMP) are the predominant motor pattern in the distal colon, and are important in both health and disease. Their origin, mechanism and relation to bioelectrical slow-waves remain incompletely understood. During abdominal surgery, an increase in the CMP occurs in the distal colon. This study aimed to evaluate the feasibility of detecting propagating slow waves and spike waves in the distal human colon through intraoperative, high-resolution (HR), serosal electrical mapping.
Methods
HR electrical recordings were obtained from the distal colon using validated flexible PCB arrays (6 × 16 electrodes; 4 mm inter-electrode spacing; 2.4 cm2, 0.3 mm diameter) for up to 15 min. Passive unipolar signals were obtained and analysed.
Results
Eleven patients (33–71 years; 6 females) undergoing colorectal surgery under general anaesthesia (4 with epidurals) were recruited. After artefact removal and comprehensive manual and automated analytics, events consistent with regular propagating activity between 2 and 6 cpm were not identified in any patient. Intermittent clusters of spike-like activities lasting 10–180 s with frequencies of each cluster ranging between 24 and 42 cpm, and an average amplitude of 0.54 ± 0.37 mV were recorded.
Conclusions
Intraoperative colonic serosal mapping in humans is feasible, but unlike in the stomach and small bowel, revealed no regular propagating electrical activity. Although sporadic, synchronous spike-wave events were identifiable. Alternative techniques are required to characterise the mechanisms underlying the hyperactive CMP observed in the intra- and post-operative period.
New findings
The aim of this study was to assess the feasibility of detecting propagating electrical activity that may correlate to the cyclic motor pattern in the distal human colon through intraoperative, high-resolution, serosal electrical mapping. High-resolution electrical mapping of the human colon revealed no regular propagating activity, but does reveal sporadic spike-wave events. These findings indicate that further research into appropriate techniques is required to identify the mechanism of hyperactive cyclic motor pattern observed in the intra- and post-operative period in humans.
Funder
Health Research Council of New Zealand
HRC Clinical Research Training Fellowship
Publisher
Springer Science and Business Media LLC
Subject
Radiology Nuclear Medicine and imaging,Biomedical Engineering,General Medicine,Biomaterials,Radiological and Ultrasound Technology
Cited by