Does the application of Opsite⋄ Flexigrid⋄ occlude the oxygen saturation readings in healthy individuals using the moorVMS-OXY machine?

Author:

Beaumont A.,McSorley L.,Matthews M.,Mooneesawmy K.,Little L.,Forss J. R.ORCID

Abstract

Abstract Background A proportion of people who have been diagnosed with peripheral arterial disease and diabetes mellitus will be susceptible to chronic wounds. Oxygen is vital for wound healing, so oxygen measurements should to be taken as predictive values for wound healing in patients. When measuring oxygen at the wound bed, there is potentially a risk of cross-infection if no protective barrier is used; and skin stripping if an adhesive barrier is used on the wound bed. This cross sectional within subject repeated measures pilot study, aims to determine if the application of opsite film, as an infection control measure, in one or two layers, impacts on tissue oxygenation readings obtained when using the MoorVMS-OXY. Methods Mean oxygen saturation percentages were measured from 29 limbs of 18 healthy participants. Oxygen saturation was measured for 20 s and analysed at the first metatarsophalangeal joint using no film, one and two layers using the MoorVMS-OXY. A one-way repeated ANOVA with a Bonferroni post hoc test was performed to test for statistically significant differences between the values of the three parameters and multiple pairwise comparisons was completed. Results Amongst the three layers, there was a statistically significant difference in oxygen saturation between the two layers of Opsite Flexigrid and none; and also between the two layers of Flexigrid and single layer (p < 0.05). It was also established that there was no statistically significant difference between the single layer of Opsite Flexigrid and no Flexigrid layer (p > 0.05). Conclusions The results imply that one layer of Opsite Flexigrid is a suitable protective barrier to use when establishing capillary bed oxygen perfusion with the MoorVMS-OXY. However, the application of two Opsite Flexigrid layers, to prevent skin stripping, decreases the recorded values of oxygen saturation percentages significantly, therefore providing inaccurate results. Indicating that a double layer cannot be used over ulceration sites if measuring oxygen levels at the wound bed.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3