Background
Legionellosis remains a public health problem. The most common diagnostic method to detect Legionella pneumophila (L. pneumophila) is culture. Polymerase chain reaction (PCR) is a fast and accurate method for this detection in environmental samples.
Methods
Four databases were searched for studies that evaluated the detection efficiency of PCR in L. pneumophila. The quality evaluation was conducted using Review Manager 5.3. We used Meta-DiSc 1.4 software and the Stata 15.0 software to create forest plots, a meta-regression, a bivariate boxplot and a Deeks’ funnel plot.
Results
A total of 18 four-fold tables from 16 studies were analysed. The overall pooled sensitivity and specificity of PCR was 94% and 72%, respectively. The positive likelihood ratio (RLR) and negative likelihood ratio (NLR) was 2.73 and 0.12, respectively. The result of the diagnostic odds ratio (DOR) was 22.85 and the area under the curve (AUC) was 0.7884.
Conclusion
Establishing a laboratory diagnostic tool for L. pneumophila detection is important for epidemiological studies. In this work, PCR demonstrated a promising diagnostic accuracy for L. pneumophila.