A novel wearable device for automated real-time detection of epileptic seizures

Author:

Habtamu Mikael,Tolosa Keneni,Abera Kidus,Demissie Lamesgin,Samuel Samrawit,Temesgen Yeabsera,Zewde Elbetel Taye,Dawud Ahmed AliORCID

Abstract

Abstract Background Epilepsy is a neurological disorder that has a variety of origins. It is caused by hyperexcitability and an imbalance between excitation and inhibition, which results in seizures. The World Health Organization (WHO) and its partners have classified epilepsy as a major public health concern. Over 50 million individuals globally are affected by epilepsy which shows that the patient’s family, social, educational, and vocational activities are severely limited if seizures are not controlled. Patients who suffer from epileptic seizures have emotional, behavioral, and neurological issues. Alerting systems using a wearable sensor are commonly used to detect epileptic seizures. However, most of the devices have no multimodal systems that increase sensitivity and lower the false discovery rate for screening and intervention of epileptic seizures. Therefore, the objective of this project was, to design and develop an efficient, economical, and automatically detecting epileptic seizure device in real-time. Methods Our design incorporates different sensors to assess the patient’s condition such as an accelerometer, pulsoxymeter and vibration sensor which process body movement, heart rate variability, oxygen denaturation, and jerky movement respectively. The algorithm for real-time detection of epileptic seizures is based on the following: acceleration increases to a higher value of 23.4 m/s2 or decreases to a lower value of 10 m/s2 as energy is absorbed by the body, the heart rate increases by 10 bpm from the normal heart rate, oxygen denaturation is below 90% and vibration should be out of the range of 3 Hz -17 Hz. Then, a pulsoxymeter device was used as a gold standard to compare the heart rate variability and oxygen saturation sensor readings. The accuracy of the accelerometer and vibration sensor was also tested by a fast-moving and vibrating normal person’s hand. Results The prototype was built and subjected to different tests and iterations. The proposed device was tested for accuracy, cost-effectiveness and ease of use. An acceptable accuracy was achieved for the accelerometer, pulsoxymeter, and vibration sensor measurements, and the prototype was built only with a component cost of less than 40 USD excluding design, manufacturing, and other costs. The design is tested to see if it fits the design criteria; the results of the tests reveal that a large portion of the scientific procedures utilized in this study to identify epileptic seizures is effective. Conclusion This project is objectively targeted to design a medical device with multimodal systems that enable us to accurately detect epileptic seizures by detecting symptoms commonly associated with an episode of epileptic seizure and notifying a caregiver for immediate assistance. The proposed device has a great impact on reducing epileptic seizer mortality, especially in low-resource settings where both expertise and treatment are scarce.

Publisher

Springer Science and Business Media LLC

Subject

Energy Engineering and Power Technology,Fuel Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3