Abstract
Abstract
Background
Ascending aortic pseudoaneurysms (AAPs) constitute a rare, albeit potentially dangerous, condition that occurs in up to 13% of patients after cardiac or aortic surgeries. For patients with a history of cardiac surgery, repeat thoracotomy poses additive risks. The high morbidity and mortality rates associated with the surgical management of AAPs have led to the development of transcatheter approaches.
Case report
We report a case of AAP percutaneous closure at the site of aortic cannulation with an ASO device in a post-CABG 65-year-old man, who refused surgery.
Conclusion
The use of the Amplatzer Atrial Septal Defect Occluder (ASO) device represents an acceptable alternative to surgery in treatment of Ascending aortic pseudoaneurysms.