Author:
Becker Lena S.,Hinrichs Jan B.
Abstract
Abstract
Background
Renal high-flow arteriovenous fistulas and its complications may involve high output heart failure, hematuria, hypertension or lethal hemorrhage.
Case presentation
This case report covers the case of a 65-year-old male patient with a large renal high-flow arteriovenous fistula of the right kidney (RAVF), treated with balloon-assisted coil and liquid (n-Butyl Cyanoacrylate) embolization. By use of ballon-occlusion with an over-the-wire Fogarty catheter and advancement of a microcatheter through the lumen distal to the balloon during the transcatheter embolization of a high-flow RAVF, control of arterial blood flow is feasible by temporary occlusion of the afferent artery. This technique of flow modulation facilitates controlled deployment of embolization materials and decreases the risk of inadvertent distal embolization by use of only one 6-French (F) arterial sheath.
Conclusions
Balloon-assisted embolization using a Fogarty occlusion catheter represents a feasible, safe and effective treatment option for the treatment of large, high-flow arteriovenous fistulas of the kidney.
Funder
Medizinische Hochschule Hannover (MHH)
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献