Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study

Author:

Sieren M. M.ORCID,Schareck C.,Kaschwich M.,Horn M.,Matysiak F.,Stahlberg E.,Wegner F.,Oechtering T. H.,Barkhausen J.,Goltz J.

Abstract

Abstract Background This study aimed to assess the error of different registration techniques and imaging modalities for fusion imaging of the aorta in a standardized setting using a anthropomorphic body phantom. Materials and methods A phantom with the 3D printed vasculature of a patient suffering from an infrarenal aortic aneurysm was constructed. Pulsatile flow was generated via an external pump. CTA/MRA of the phantom was performed, and a virtual 3D vascular model was computed. Subsequently, fusion imaging was performed employing 3D-3D and 2D-3D registration techniques. Accuracy of the registration was evaluated from 7 right/left anterior oblique c-arm angulations using the agreement of centerlines and landmarks between the phantom vessels and the virtual 3D virtual vascular model. Differences between imaging modalities were assessed in a head-to-head comparison based on centerline deviation. Statistics included the comparison of means ± standard deviations, student’s t-test, Bland-Altman analysis, and intraclass correlation coefficient for intra- and inter-reader analysis. Results 3D-3D registration was superior to 2D-3D registration, with the highest mean centerline deviation being 1.67 ± 0.24 mm compared to 4.47 ± 0.92 mm. The highest absolute deviation was 3.25 mm for 3D-3D and 6.25 mm for 2D-3D registration. Differences for all angulations between registration techniques reached statistical significance. A decrease in registration accuracy was observed for c-arm angulations beyond 30° right anterior oblique/left anterior oblique. All landmarks (100%) were correctly positioned using 3D-3D registration compared to 81% using 2D-3D registration. Differences in accuracy between CT and MRI were acceptably small. Intra- and inter-reader reliability was excellent. Conclusion In the realm of registration techniques, the 3D-3D method proved more accurate than did the 2D-3D method. Based on our data, the use of 2D-3D registration for interventions with high registration quality requirements (e.g., fenestrated aortic repair procedures) cannot be fully recommended. Regarding imaging modalities, CTA and MRA can be used equivalently.

Funder

BMBF

Universität zu Lübeck

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3