Abstract
Abstract
Background
Laparoscopic splenectomy for patients with portal hypertension is associated with a high risk of bleeding. The use of vessel-sealing devices and automatic sutures is important for bleeding control. However, a rare complication of abdominal surgery is the direct communication between the arterial and portal circulation related to surgical procedures such as simultaneous ligature of an artery and adjacent vein. We describe a rare case of omental arteriovenous fistula (AVF) after laparoscopic splenectomy treated with transarterial embolization.
Case presentation
We report a case of a 46-year-old male patient with an omental AVF after a laparoscopic splenectomy 6 years ago for splenomegaly associated with alcoholic cirrhosis. Follow-up abdominal dynamic computed tomography accidentally revealed a vascular sac (25 mm in the major axis) that formed an omental AVF with anastomosis to the left colonic vein. The communication was considered to be caused by using a vessel-sealing device. No symptoms related to the AVF were observed. The AVF was embolized with microcoils using the transarterial approach. A 4-axis catheter system was used for accurate embolization due to the long and tortuous distance from the celiac artery. No recurrence or symptoms were observed after 6 months.
Conclusions
Treatment of arterioportal fistula is mandatory, even in asymptomatic patients. Embolization is a less invasive alternative to surgical approaches. The 4-axis catheter system was useful for accurate embolization via a long and tortuous artery.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献