Abstract Background To evaluate the dosimetric impact of variable bladder filling on target and organ at risk (OARs) in cervical cancer patients undergoing chemoradiation. Forty consecutive patients with cervical cancer underwent radiotherapy planning as per the departmental protocol. All patients were asked to empty their bowel and bladder before simulation and catheterization was done. Normal saline was instilled into the bladder through Foleys till the patient had a maximal urge to urinate. Pelvic cast fabrication and CT simulation was done. Then, 30%, 50%, and 100% of the instilled saline was removed and rescans taken. Planning was done on full bladder (X) and the same plan applied to the contours with bladder volumes 0.7X (PLAN70), 0.5X (PLAN50), and empty (PLAN0). A dose of 50 Gy/25# was prescribed to the PTV and plans evaluated. Intensity-modulated radiotherapy plans with full bladder were implemented for each patient. Shifts in the center of mass (COM) of the cervix/uterus with variable bladder filling identified were noted. Statistical analysis was performed using SPSS software. A p value < 0.05 was considered significant. Results Bladder volume in 70%, 50%, and empty bladder planning was 78.34% (388.35 + 117.44 ml), 64.44% (320.60 + 106.20 ml), and 13.63% (62.60 + 23.12 ml), respectively. The mean dose received by 95% PTV was 49.76 Gy + 1.30 Gy. Though the difference in target coverage was significant between PLAN100 and other plans, the mean difference was minimal. A decrease in bladder filling resulted in an increase in OAR dose. Variation in the increase in dose to OARs was not significant if bladder filling was > 78.34% and > 64.44% of a full bladder with respect to the bowel and rectal/bladder doses, respectively. Inconsistent bladder filling led to a maximal shift in COM (uterus/cervix) in the Y- and Z-axis. Conclusion Bladder filling variations have an impact on cervico-uterine motion/shape, thereby impacting the dose to the target and OARs. It is recommended to have a threshold bladder volume of at least 70–75% of optimally filled bladder during daily treatment. Trial registration Institutional review board (IRB) registered by Drug Controller General (India) with registration number ECR/10/Ins/DC/2013. Trial Registration number - RGCIRC/IRB/44/2016, registered and approved on the 14th of May 2016.

Publisher

Springer Science and Business Media LLC

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3