Author:
Thomann Janine,Rüegger Christoph M.,Gaertner Vincent D.,O’Currain Eoin,Kamlin Omar F.,Davis Peter G.,Springer Laila
Abstract
Abstract
Background
We sought to assess tidal volumes in (near) term infants during delivery room stabilization.
Methods
Secondary analysis of a prospective study comparing two facemasks used for positive pressure ventilation (PPV) in newborn infants ≥ 34 weeks gestation. PPV was provided with a T-piece device with a PIP of 30 cmH2O and positive end-expiratory airway pressure of 5 cmH2O. Expired tidal volumes (Vt) were measured with a respiratory function monitor. Target range for Vt was defined to be 4 – 8 ml/kg.
Results
Twenty-three infants with a median (IQR) gestational age of 38.1 (36.4 – 39.0) weeks received 1828 inflations with a median Vt of 4.6 (3.3 – 6.2) ml/kg. Median Vt was in the target range in 12 infants (52%), lower in 9 (39%) and higher in 2 (9%). Thirty-six (25—27) % of the inflations were in the target rage over the duration of PPV while 42 (25 – 65) % and 10 (3 – 33) % were above and below target range.
Conclusions
Variability of expiratory tidal volume delivered to term and late preterm infants was wide. Reliance on standard pressures and clinical signs may be insufficient to provide safe and effective ventilation in the delivery room.
Trial registration
This is a secondary analysis of a prospectively registered randomized controlled trial (ACTRN12616000768493).
Funder
University of Zurich, Filling the Gap
Publisher
Springer Science and Business Media LLC
Subject
Pediatrics, Perinatology and Child Health
Reference20 articles.
1. Madar J, Roehr CC, Ainsworth S, Ersdal H, Morley C, Rudiger M, et al. European resuscitation council guidelines 2021: newborn resuscitation and support of transition of infants at birth. Resuscitation. 2021;161:291–326.
2. Perlman JM, Wyllie J, Kattwinkel J, Wyckoff MH, Aziz K, Guinsburg R, et al. Part 7: Neonatal resuscitation: 2015 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Circulation. 2015;132(16 Suppl 1):S204–41.
3. Klingenberg C, Wheeler KI, McCallion N, Morley CJ, Davis PG. Volume-targeted versus pressure-limited ventilation in neonates. Cochrane Database Syst Rev. 2017;10:CD003666.
4. Mian Q, Cheung PY, O’Reilly M, Barton SK, Polglase GR, Schmölzer GM. Impact of delivered tidal volume on the occurrence of intraventricular haemorrhage in preterm infants during positive pressure ventilation in the delivery room. Arch Dis Child Fetal Neonatal Ed. 2019;104(1):F57–62.
5. Schmolzer GM, Dawson JA, Kamlin CO, O’Donnell CP, Morley CJ, Davis PG. Airway obstruction and gas leak during mask ventilation of preterm infants in the delivery room. Arch Dis Child Fetal Neonatal Ed. 2011;96(4):F254–7.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献