EEG monitoring during anesthesia in children aged 0 to 18 months: amplitude-integrated EEG and age effects

Author:

Schultz Barbara,Schultz Michael,Boehne Martin,Dennhardt Nils

Abstract

Abstract Background The amplitude-integrated EEG (aEEG) is a widely used monitoring tool in neonatology / pediatric intensive care. It takes into account the amplitudes, but not the frequency composition, of the EEG. Advantages of the aEEG are clear criteria for interpretation and time compression. During the first year of life, the electroencephalogram (EEG) during sedation / anesthesia changes from a low-differentiated to a differentiated EEG; higher-frequency waves develop increasingly. There are few studies on the use of aEEG during pediatric anesthesia. A systematic evaluation of the aEEG in defined EEG stages during anesthesia / sedation is not yet available. Parameters of pediatric EEGs (power, median frequency, spectral edge frequency) recorded during anesthesia and of the corresponding aEEGs (upper and lower value of the aEEG trace) should be examined for age-related changes. Furthermore, it should be examined whether the aEEG can distinguish EEG stages of sedation / anesthesia in differentiated EEGs. Methods In a secondary analysis of a prospective observational study EEGs and aEEGs (1-channel recordings, electrode positions on forehead) of 50 children (age: 0–18 months) were evaluated. EEG stages: A (awake), Slow EEG, E2, F0, and F1 in low-differentiated EEGs and A (awake), B0–2, C0–2, D0–2, E0–2, F0–1 in differentiated EEGs. Results Median and spectral edge frequency increased significantly with age (p < 0.001 each). In low-differentiated EEGs, the power of the Slow EEG increased significantly with age (p < 0.001). In differentiated EEGs, the power increased significantly with age in each of the EEG stages B1 to E1 (p = 0.04, or less), and the upper and lower values of the aEEG trace increased with age (p < 0.001). A discriminant analysis using the upper and lower values of the aEEG showed that EEG epochs from the stages B1 to E1 were assigned to the original EEG stage in only 19.3% of the cases. When age was added as the third variable, the rate of correct reclassifications was 28.5%. Conclusions The aEEG was not suitable for distinguishing EEG stages above the burst suppression range. For this purpose, the frequency composition of the EEG should be taken into account.

Funder

Medizinische Hochschule Hannover (MHH)

Publisher

Springer Science and Business Media LLC

Subject

Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3