Hematological reference intervals are used for medical decision tools for interpretation of numerical test results. Establishing of hematological interval among newborn babies is very important for the diagnosis of malignancy, anemia, bleeding disorders, and various infections. There are no locally established hematological reference intervals in Ethiopia. Thus, the aim of this study is to establish locally determined hematological reference interval among full-term newborns.
Methods
A cross-sectional study was conducted from May 15 to July 30 2019 among 151 apparently healthy full-term newborns at Gondar University Hospital. About 3 ml of cord blood was obtained for analysis of Hematological parameters and determined by using Sysmex KX-21N (Sysmex Corporation Kobe, Japan) automated analyzer. Median, 2.5th and 97.5th percentile were computed.
Result
Male to female ratio was almost equal. All hematological parameter had no statistically significant difference between males and females. The delivery types were not influenced its hematological values. The reference interval of white blood cells, red blood cells, platelets, hemoglobin, hematocrit, mean cell volume, and mean cell hemoglobin were (7.64–22.16) x109/l, (3.69–5.47)x1012/l, (132.74–413.4) x109/l, (13.32–19.64) g/dl and (39.42–58.06)%, (91.6-113.22)fl, and (30.48–38.02 pg), respectively.
Conclusions
All hematological reference intervals were established from full-term newborns at University of Gondar hospital was different from other studies in Nigeria, Iraq, Pakistan, Nepal, Saudi Arabia and Iran. Therefore, own determined reference value is very important for the clinicians to correctly diagnosis the patients at health facility levels.
Publisher
Springer Science and Business Media LLC
Subject
Pediatrics, Perinatology, and Child Health
Reference27 articles.
1. Katsares V, Paparidis Z, Nikolaidou E, Karvounidou I, Ardelean K-A, Drossas N, et al. Reference ranges for umbilical cord blood hematological values. Laboratory Medicine. 2009;40(7):437–9.
2. Wiedmeier SE, Henry E, Sola-Visner M, Christensen R. Platelet reference ranges for neonates, defined using data from over 47 000 patients in a multihospital healthcare system. Journal of perinatology. 2009;29(2):130–6.
3. Wall D. Umbilical cord blood: importance of supporting public banks. 2011. p. 638.
4. Carroll P, Nankervis C, Iams J, Kelleher K. Umbilical cord blood as a replacement source for admission complete blood count in premature infants. J Perinatol. 2012;32(2):97.
5. Slhessarenko N, Andriolo A. The importance of determining reference intervals for Laboratory Medicine. Jornal Brasileiro de Patologia e Medicina Laboratorial. 2016;52(2):68–9.