Author:
Sancar Nuriye,Tabrizi Sahar S.
Abstract
Abstract
Background
After the World Health Organization declared the COVID-19 pandemic, the role of Vitamin D has become even more critical for people worldwide. The most accurate way to define vitamin D level is 25-hydroxy vitamin D(25-OH-D) blood test. However, this blood test is not always feasible. Most data sets used in health science research usually contain highly correlated features, which is referred to as multicollinearity problem. This problem can lead to misleading results and overfitting problems in the ML training process. Therefore, the proposed study aims to determine a clinically acceptable ML model for the detection of the vitamin D status of the North Cyprus adult participants accurately, without the need to determine 25-OH-D level, taking into account the multicollinearity problem.
Method
The study was conducted with 481 observations who applied voluntarily to Internal Medicine Department at NEU Hospital. The classification performance of four conventional supervised ML models, namely, Ordinal logistic regression(OLR), Elastic-net ordinal regression(ENOR), Support Vector Machine(SVM), and Random Forest (RF) was compared. The comparative analysis is performed regarding the model's sensitivity to the participant’s metabolic syndrome(MtS)'positive status, hyper-parameter tuning, sensitivities to the size of training data, and the classification performance of the models.
Results
Due to the presence of multicollinearity, the findings showed that the performance of the SVM(RBF) is obviously negatively affected when the test is examined. Moreover, it can be obviously detected that RF is more robust than other models when the variations in the size of training data are examined. This experiment's result showed that the selected RF and ENOR showed better performances than the other two models when the size of training samples was reduced. Since the multicollinearity is more severe in the small samples, it can be concluded that RF and ENOR are not affected by the presence of the multicollinearity problem. The comparative analysis revealed that the RF classifier performed better and was more robust than the other proposed models in terms of accuracy (0.94), specificity (0.96), sensitivity or recall (0.94), precision (0.95), F1-score (0.95), and Cohen's kappa (0.90).
Conclusion
It is evident that the RF achieved better than the SVM(RBF), ENOR, and OLR. These comparison findings will be applied to develop a Vitamin D level intelligent detection system for being used in routine clinical, biochemical tests, and lifestyle characteristics of individuals to decrease the cost and time of vitamin D level detection.
Publisher
Springer Science and Business Media LLC
Subject
Health Informatics,Health Policy,Computer Science Applications
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献