Abstract
Abstract
Background
The aim of this study was to examine left ventricular (LV) function in untreated, newly diagnosed hypertensive patients with morning blood pressure surge (MBPS) status using three-dimensional (3D) speckle tracking echocardiography (STE).
Methods
In this study, 163 newly diagnosed hypertensive patients were included, and all patients underwent 24-h ambulatory blood pressure monitoring (ABPM). According to ABPM, participants were divided into a MBPS group and a non-MBPS group. The entire study population was examined by complete two-dimensional (2D) transthoracic echocardiography (TTE) and 3D STE.
Result
The results of this study showed that 3D LV longitudinal strain was significantly decreased in the MBPS group compared with the non-MBPS group (− 30.1 ± 2.0 vs. -31.1 ± 2.7, p = 0.045). Similar trends were observed for 3D twist (9.6 ± 6.1 vs. 12.1 ± 4.8, p = 0.011) as well as for 3D torsion (1.23 ± 0.78 vs. 1.49 ± 0.62, p = 0.042). The LV principal strain was decreased in the MBPS group (− 33.9 ± 1.7 vs. -35.5 ± 2.8, p < 0.001). The 3D LV global longitudinal strain (GLS) and principal strain were significantly associated with quartile of MBPS as measured by systolic blood pressure (SBP).
Conclusion
The 3D STE revealed that LV mechanics were more impaired in the MBPS group than in the non-surge newly diagnosed, untreated hypertensive patients; even the 2D TTE parameters showed no difference.
Funder
the Korea Society of Hypertension
Publisher
Springer Science and Business Media LLC
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献