Abstract
Abstract
Background
Electroacupuncture (EA) is often used in clinical settings due to its analgesic effect, but its safety has not been verified due to the lack of clear criteria. This study examined the critical range of the corrosion of stainless steel types STS304 and STS316, which have been used clinically, and the relationship between needle corrosion and cell necrosis.
Method
The critical point of corrosion for STS304 and STS316 was identified by varying the time, frequency, and stimulation intensity. In a tissue necrosis experiment, EA stimulation was applied to rats using STS316 needles with different thicknesses at maximum intensity for 60 min, and the presence of corrosion and tissue necrosis was determined. A cytotoxicity experiment was also conducted and assessed the needles and tissue necrosis.
Results
The results showed that STS316 was more stable than STS304 and that only coated needles corroded. Furthermore, tissue necrosis was observed regardless of corrosion, and slight cell necrosis was associated with needles with corrosion.
Conclusions
This study demonstrated that non-coated STS316 was the most stable for EA stimulation and that corrosion byproducts and cell necrosis were not directly related.
Publisher
Springer Science and Business Media LLC
Subject
Complementary and alternative medicine,General Medicine
Reference18 articles.
1. Zhang R, Lao L, Ren K, Berman BM. Mechanisms of acupuncture-electroacupuncture on persistent pain. Anesthesiology. 2014;120(2):482–503.
2. Chang FC, Tsai HY, Yu MC, Yi PL, Lin JG. The central serotonergic system mediates the analgesic effect of electroacupuncture on ZUSANLI (ST36) acupoints. J Biomed Sci. 2004;11(2):179–85.
3. Mayor D. An exploratory review of the electroacupuncture literature: clinical applications and endorphin mechanisms. Acupunct Med. 2013;31(4):409–15.
4. Floroian L, Samoila C, Badea M, Munteanu D, Ristoscu C, Sima F, Negut I, Chifiriuc MC, Mihailescu IN. Stainless steel surface biofunctionalization with PMMA-bioglass coatings: compositional, electrochemical corrosion studies and microbiological assay. J Mater Sci Mater Med. 2015;26(6):195.
5. Es-Souni M, Es-Souni M, Fischer-Brandies H. Assessing the biocompatibility of NiTi shape memory alloys used for medical applications. Anal Bioanal Chem. 2005;381(3):557–67.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献