Treatment outcomes of carotid artery stenting with two types of distal protection filter device

Author:

Iko Minoru,Aikawa Hiroshi,Go Yoshinori,Nakai Kanji,Tsutsumi Masanori,Yu Iwae,Mizokami Taichiro,Sakamoto Kimiya,Inoue Ritsuro,Mitsutake Takafumi,Eto Ayumu,Hanada Hayatsura,Kazekawa Kiyoshi

Abstract

Abstract Purpose Preventing cerebral embolism from debris produced during carotid artery stenting (CAS) is important. This study compared the treatment outcomes of CAS using two types of filter-based embolic protection devices currently in use in Japan. Materials and methods We assessed 121 consecutive cases of CAS performed with FilterWire EZ™ between July 2010 and November 2012 and 37 consecutive cases of CAS performed with the Spider FX™ between November 2012 and June 2013. A Carotid Wallstent™ was used in all cases. The incidence of positive lesions on diffusion-weighted magnetic resonance imaging (DWI) and stroke were compared between the groups. Results Postoperative DWI-positive lesions were observed in 38 (31.4%) and 14 (37.8%) patients in the FilterWire and Spider groups, respectively. In the FilterWire group, complications were transient ischemic attacks in 3 (2.5%) patients, cerebral infarction in 2 (1.7%) patients (1 patient each with minor and major stroke), and cerebral hemorrhage due to hyperperfusion syndrome in 1 (0.8%) patient. In the Spider group, except for cerebral infarction (minor stroke) in 1 (2.7%) patient, no complications were observed. No significant differences were observed in the incidence of complications between the groups. Conclusion FilterWire EZ and Spider FX are comparable in terms of treatment outcome.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Reference21 articles.

1. Bates ER, Babb JD, Casey DE Jr, Cates CU, Duckwiler GR, Feldman TE, Gray WA, Ouriel K, Peterson ED, Rosenfield K, Rundback JH, Safian RD, Sloan MA, White CJ: ACCF/SCAI/SVMB/SIR/ASITN 2007 clinical expert consensus document on carotid stenting: a report of the American College of Cardiology Foundation Task Force on Clinical Expert Consensus Documents (ACCF/SCAI/SVMB/SIR/ASITN Clinical Expert Consensus Document Committee on Carotid Stenting). J Am Coll Cardiol 2007, 49(1):126-170. 10.1016/j.jacc.2006.10.021

2. Brott TG, Hobson RW 2nd, Howard G, Roubin GS, Clark WM, Brooks W, Mackey A, Hill MD, Leimgruber PP, Sheffet AJ, Howard VJ, Moore WS, Voeks JH, Hopkins LN, Cutlip DE, Cohen DJ, Popma JJ, Ferguson RD, Cohen SN, Blackshear JL, Silver FL, Mohr JP, Lal BK, Meschia JF, CREST Investigators: Stenting versus endarterectomy for treatment of carotid-artery stenosis. N Engl J Med 2010, 363(1):11-23. 10.1056/NEJMoa0912321

3. Casserly IP, Abou-Chebl A, Fathi RB, Lee DS, Saw J, Exaire JE, Kapadia SR, Bajzer CT, Yadav JS: Slow-flow phenomenon during carotid artery intervention with embolic protection devices: predictors and clinical outcome. J Am Coll Cardiol 2005, 46(8):1466-1472. 10.1016/j.jacc.2005.05.082

4. Iko M, Tsutsumi M, Aikawa H, Matsumoto Y, Go Y, Nii K, Abe G, Ye I, Nomoto Y, Kazekawa K: Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon. Jpn J Radiol 2013, 31(1):45-49. 10.1007/s11604-012-0145-9

5. Iyer V, de Donato G, Deloose K, Peeters P, Castriota F, Cremonesi A, Setacci C, Bosiers M: The type of embolic protection does not influence the outcome in carotid artery stenting. J Vasc Surg 2007, 46(2):251-256. 10.1016/j.jvs.2007.04.053

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3