Development of an enzyme-linked immunosorbent assay for the detection of human calretinin in plasma and serum of mesothelioma patients

Author:

Raiko Irina,Sander Ingrid,Weber Daniel G,Raulf-Heimsoth Monika,Gillissen Adrian,Kollmeier Jens,Scherpereel Arnaud,Brüning Thomas,Johnen Georg

Abstract

Abstract Background Calretinin is one of the well-established immunohistochemical markers in the diagnostics of malignant mesothelioma (MM). Its utility as a diagnostic tool in human blood, however, is scarcely investigated. The aim of this study was to develop an enzyme-linked immunosorbent assay (ELISA) for human calretinin in blood and to assess its usefulness as a potential minimally invasive diagnostic marker for MM. Methods Initially, attempts were made to establish an assay using commercially available antibodies and to optimize it by including a biotin-streptavidin complex into the assay protocol. Subsequently, a novel ELISA based on polyclonal antibodies raised in rabbit immunized with human recombinant calretinin was developed. The assay performance in human serum and plasma (EDTA/heparin) and the influence of calcium concentrations on antibody recognition were studied. Stability of spiked-in calretinin in EDTA plasma under different storage conditions was also examined. In preliminary studies serum and plasma samples from 97 healthy volunteers, 35 asbestos-exposed workers, and 42 MM patients were analyzed. Results The mean detection range of the new ELISA was 0.12 to 8.97 ng/ml calretinin. The assay demonstrated markedly lower background and significantly higher sensitivity compared to the initially contrived assay that used commercial antibodies. Recovery rate experiments confirmed dependence of calretinin antibody recognition on calcium concentration. Calcium adjustment is necessary for calretinin measurement in EDTA plasma. Spiked-in calretinin revealed high stability in EDTA plasma when stored at room temperature, 4°C, or after repeated freeze/thaw cycles. Median calretinin values in healthy volunteers, asbestos workers, and MM patients were 0.20, 0.33, and 0.84 ng/ml, respectively (p < 0.0001 for healthy vs. MM, p = 0.0036 for healthy vs. asbestos-exposed, p < 0.0001 for asbestos-exposed vs. MM). Median values in patients with epithelioid and biphasic MM were similar. No influence of age, gender, smoking status, or type of medium (plasma/serum) on calretinin values was found. Conclusions The novel assay is highly sensitive and applicable to human serum and plasma. Calretinin appears to be a promising marker for the blood-based detection of MM and might complement other markers. However, further studies are required to prove its usefulness in the diagnosis of MM patients.

Publisher

Springer Science and Business Media LLC

Subject

Cancer Research,Genetics,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3