Author:
Nicolini Andrea,Tartarelli Gianna,Carpi Angelo,Metelli Maria Rita,Ferrari Paola,Anselmi Loretta,Conte Massimo,Berti Piero,Miccoli Paolo
Abstract
Abstract
Background
In breast cancer current guidelines do not recommend the routine use of serum tumour markers. Differently, we observed that CEA-TPA-CA15.3 (carcinoembryonic (CEA) tissue polypeptide (TPA) and cancer associated 115D8/DF3 (CA15.3) antigens) panel permits early detection and treatment for most relapsing patients. As high sensitivity and specificity and different cut-off values have been reported for mucin-like carcinoma associated antigen (MCA), we compared MCA with the above mentioned tumour markers and MCA-CA15.3 with the CEA-TPA-CA15.3 panel.
Methods
In 289 breast cancer patients submitted to an intensive post-operative follow-up with tumour markers, we compared MCA (cut-off values, ≥ 11 and ≥ 15 U/mL) with CEA or CA15.3 or TPA for detection of relapse. In addition, we compared the MCA-CA15.3 and CEA-TPA-CA15.3 tumour marker panels.
Results
Distant metastases occurred 19 times in 18 (6.7%) of the 268 patients who were disease-free at the beginning of the study. MCA sensitivity with both cut-off values was higher than that of CEA or TPA or CA15.3 (68% vs 10%, 26%, 32% and 53% vs 16%, 42%, 32% respectively). With cut-off ≥ 11 U/mL, MCA showed the lowest specificity (42%); with cut-off ≥ 15 U/mL, MCA specificity was similar to TPA (73% vs 72%) and lower than that of CEA and CA15.3 (96% and 97% respectively). With ≥ 15 U/mL MCA cut-off, MCA sensitivity increased from 53% to 58% after its association with CA15.3. Sensitivity of CEA-TPA-CA15.3 panel was 74% (14 of 19 recurrences). Eight of the 14 recurrences early detected with CEA-TPA-CA15.3 presented as a single lesion (oligometastatic disease) (5) or were confined to bony skeleton (3) (26% and 16% respectively of the 19 relapses). With ≥ 11 U/mL MCA cut-off, MCA-CA15.3 association showed higher sensitivity but lower specificity, accuracy and positive predictive value than the CEA-TPA-CA15.3 panel.
Conclusion
At both the evaluated cut-off values serum MCA sensitivity is higher than that of CEA, TPA or CA15.3 but its specificity is similar to or lower than that of TPA. Overall, CEA-TPA-CA15.3 panel is more accurate than MCA-CA15.3 association and can "early" detect a few relapsed patients with limited metastatic disease and more favourable prognosis. These findings further support the need for prospective randomised clinical trial to assess whether an intensive post-operative follow-up with an appropriate use of serum tumour markers can significantly improve clinical outcome of early detected relapsing patients.
Publisher
Springer Science and Business Media LLC
Subject
Cancer Research,Genetics,Oncology
Cited by
52 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献