Evaluating the consistency in different methods for measuring left atrium diameters

Author:

Yue Jun-Yan,Ji Kai,Liu Hai-Peng,Wu Qing-Wu,Liang Chang-Hua,Gao Jian-Bo

Abstract

Abstract Background The morphological information of the pulmonary vein (PV) and left atrium (LA) is of immense clinical importance for effective atrial fibrillation ablation. The aim of this study is to examine the consistency in different LA diameter measurement techniques. Methods Retrospective imaging data from 87 patients diagnosed with PV computed tomography angiography were included. The patients consisted of 50 males and 37 females, with an average age of (60.74 ± 8.70) years. Two physicians independently measured the anteroposterior diameter, long diameter, and transverse diameter of the LA using six different methods. Additionally, we recorded the post-processing time of the images. Physician 1 conducted measurements twice with a one-month interval between the measurements to assess intra-rater reliability. Using the intraclass correlation coefficient (ICC), the consistency of each LA diameter measurement by the two physicians was evaluated. We compared the differences in the LA diameter and the time consumed for measurements using different methods. This was done by employing the rank sum test of a randomized block design (Friedman M test) and the q test for pairwise comparisons among multiple relevant samples. Results (1) The consistency of the measured LA diameter by the two physicians was strong or very strong. (2) There were statistical differences in the anteroposterior diameter, long diameter, and transverse diameter of LA assessed using different methods (χ2 = 222.28, 32.74, 293.83, P < 0.001). (3) Different methods for measuring the diameters of LA required different amounts of time (χ2 = 333.10, P < 0.001). Conclusion The results of left atrium (LA) diameter measurements conducted by different physicians were found to be reliable. However, the LA diameters obtained through various techniques exhibited variations. It was observed that measuring LA long diameters using only the VR (volume rendering) picture was the most clinically applicable method.

Funder

the 2018 Henan province key technologies research and development program

the 2017 Key research project of Heart Center of the First Affiliated Hospital of Xinxiang Medical College

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3