Author:
Penn Alan,Medved Milica,Abe Hiroyuki,Dialani Vandana,Karczmar Gregory S.,Brousseau David
Abstract
Abstract
Background
Thresholding apparent diffusion coefficient (ADC) maps obtained from Diffusion-Weighted-Imaging (DWI) has been proposed for identifying benign lesions that can safely avoid biopsy. The presence of malignancies with high ADC values leads to high thresholds, limiting numbers of avoidable biopsies.
Purpose
We evaluate two previously reported methods for identifying avoidable biopsies: using case-set dependent ADC thresholds that assure 100% sensitivity and using negative likelihood ratio (LR-) with a fixed ADC threshold of 1.50 × 10–3 mm2/s. We evaluated improvements in efficacy obtained by excluding non-mass lesions and lesions with anisotropic intra-lesion morphologic characteristics.
Study type
Prospective.
Population
55 adult females with dense breasts with 69 BI-RADS 4 or 5 lesions (38 malignant, 31 benign) identified on ultrasound and mammography and imaged with MRI prior to biopsy.
Field strength/sequence
1.5 T and 3.0 T. DWI.
Assessment
Analysis of DWI, including directional images was done on an ROI basis. ROIs were drawn on DWI images acquired prior to biopsy, referencing all available images including DCE, and mean ADC was measured. Anisotropy was quantified via variation in ADC values in the lesion core across directional DWI images.
Statistical tests
Improvement in specificity at 100% sensitivity was evaluated with exact McNemar test with 1-sided p-value < 0.05 indicating statistical significance.
Results
Using ADC thresholding that assures 100% sensitivity, non-mass and directional variance filtering improved the percent of avoidable biopsies to 42% from baseline of 10% achieved with ADC thresholding alone. Using LR-, filtering improved outcome to 0.06 from baseline 0.25 with ADC thresholding alone. ADC thresholding showed a lower percentage of avoidable biopsies in our cohort than reported in prior studies. When ADC thresholding was supplemented with filtering, the percentage of avoidable biopsies exceeded those of prior studies.
Data conclusion
Supplementing ADC thresholding with filters excluding non-mass lesions and lesions with anisotropic characteristics on DWI can result in an increased number of avoidable biopsies.
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging