Relationship of shear wave elastography anisotropy with tumor stem cells and epithelial-mesenchymal transition in breast cancer

Author:

Leng Xiaoling,Japaer Rexida,Zhang Haijian,Yeerlan Mila,Ma Fucheng,Ding Jianbing

Abstract

Abstract Background This study is to examine the feasibility of shear wave elastography (SWE) anisotropy in assessing the prognosis of breast cancer. Methods We enrolled 119 breast cancer patients from January 2017 to October 2019. SWE was performed before operation. Emax (maximum elasticity value), Emean (average elasticity value), Esd (standard deviation of the lesion elasticity value), Eratio (elasticity value of adipose tissue), anisotropy coefficient and difference were recorded. After operation, we collected clinical pathological data, and performed immunohistochemistry and real-time PCR tests on CD44, CD24, E-cadherin, β-catenin, vimentin and N-cadherin. Finally, we analyzed the correlation among parameters of SWE, anisotropy and clinicopathology, and markers of CSCs (cancer stem cells) and EMT (epithelial-mesenchymal transition). Results Emax, Emean and Esd of the cross section were higher than those of the longitudinal section. Breast cancer with a higher elastic modulus was often accompanied by a hyperechoic halo, which was manifested as mixed echo and post-echo attenuation, and was accompanied by a higher BI-RADS (breast imaging reporting and data system) classification. When breast cancer had hyperechoic halo and weakened posterior echo, SWE of the lesion showed more obvious anisotropy. In addition, larger diameter of the longitudinal section indicated higher stiffness of the cross section. Correlation analysis showed that E-cadherin was negatively correlated with SWE in longitudinal section. CD44, N-cadherin, β-catenin were positively correlated with SWE in longitudinal and cross sections. Vimentin and CD24 had no correlation with SWE parameters. Conclusion SWE of breast cancer is anisotropic. The cross-sectional SWE is better than the longitudinal SWE, Emax is better than Emean, the anisotropy of SWE is better than SWE, and the anisotropy factor is better than the anisotropy difference.

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3