Author:
Lin Yu-Chun,Chen Meng-Chi,Chen Cheng-Hsueh,Chen Mu-Hsiung,Liu Kang-Yi,Chang Cheng-Chun
Abstract
Abstract
Background
Dental film mounting is an essential but time-consuming task in dental radiography, with manual methods often prone to errors. This study aims to develop a deep learning (DL) model for accurate automated classification and mounting of both intraoral and extraoral dental radiography.
Method
The present study employed a total of 22,334 intraoral images and 1,035 extraoral images to train the model. The performance of the model was tested on an independent internal dataset and two external datasets from different institutes. Images were categorized into 32 tooth areas. The VGG-16, ResNet-18, and ResNet-101 architectures were used for pretraining, with the ResNet-101 ultimately being chosen as the final trained model. The model’s performance was evaluated using metrics of accuracy, precision, recall, and F1 score. Additionally, we evaluated the influence of misalignment on the model’s accuracy and time efficiency.
Results
The ResNet-101 model outperformed VGG-16 and ResNet-18 models, achieving the highest accuracy of 0.976, precision of 0.969, recall of 0.984, and F1-score of 0.977 (p < 0.05). For intraoral images, the overall accuracy remained consistent across both internal and external datasets, ranging from 0.963 to 0.972, without significant differences (p = 0.348). For extraoral images, the accuracy consistently achieved the highest value of 1 across all institutes. The model’s accuracy decreased as the tilt angle of the X-ray film increased. The model achieved the highest accuracy of 0.981 with correctly aligned films, while the lowest accuracy of 0.937 was observed for films exhibiting severe misalignment of ± 15° (p < 0.001). The average time required for the tasks of image rotation and classification for each image was 0.17 s, which was significantly faster than that of the manual process, which required 1.2 s (p < 0.001).
Conclusion
This study demonstrated the potential of DL-based models in automating dental film mounting with high accuracy and efficiency. The proper alignment of X-ray films is crucial for accurate classification by the model.
Funder
Chang Gung Memorial Hospital, Linkou
National Taipei University of Technology
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging
Reference15 articles.
1. Praskalo J, Beganović A, Milanović J, Stanković K, INTRAORAL DENTAL X-RAY RADIOGRAPHY IN BOSNIA AND HERZEGOVINA: STUDY FOR REVISING DIAGNOSTIC REFERENCE LEVEL VALUE. Radiat Prot Dosimetry. 2020;190(1):90–9.
2. Favia G, Lacaita MG, Limongelli L, Tempesta A, Laforgia N, Cazzolla AP, Maiorano E. Hyperphosphatemic familial tumoral calcinosis: odontostomatologic management and pathological features. Am J Case Rep. 2014;15:569–75.
3. Woodward TM. Dental radiology. Top Companion Anim Med. 2009;24(1):20–36.
4. Zhang W, Huynh CP, Abramovitch K, Leon IL, Arvizu L. Comparison of technique errors of intraoral radiographs taken on film v photostimulable phosphor (PSP) plates. Tex Dent J. 2012;129(6):589–96.
5. Chan HP, Samala RK, Hadjiiski LM, Zhou C. Deep learning in Medical Image Analysis. Adv Exp Med Biol. 2020;1213:3–21.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献