Fully automated film mounting in dental radiography: a deep learning model

Author:

Lin Yu-Chun,Chen Meng-Chi,Chen Cheng-Hsueh,Chen Mu-Hsiung,Liu Kang-Yi,Chang Cheng-Chun

Abstract

Abstract Background Dental film mounting is an essential but time-consuming task in dental radiography, with manual methods often prone to errors. This study aims to develop a deep learning (DL) model for accurate automated classification and mounting of both intraoral and extraoral dental radiography. Method The present study employed a total of 22,334 intraoral images and 1,035 extraoral images to train the model. The performance of the model was tested on an independent internal dataset and two external datasets from different institutes. Images were categorized into 32 tooth areas. The VGG-16, ResNet-18, and ResNet-101 architectures were used for pretraining, with the ResNet-101 ultimately being chosen as the final trained model. The model’s performance was evaluated using metrics of accuracy, precision, recall, and F1 score. Additionally, we evaluated the influence of misalignment on the model’s accuracy and time efficiency. Results The ResNet-101 model outperformed VGG-16 and ResNet-18 models, achieving the highest accuracy of 0.976, precision of 0.969, recall of 0.984, and F1-score of 0.977 (p < 0.05). For intraoral images, the overall accuracy remained consistent across both internal and external datasets, ranging from 0.963 to 0.972, without significant differences (p = 0.348). For extraoral images, the accuracy consistently achieved the highest value of 1 across all institutes. The model’s accuracy decreased as the tilt angle of the X-ray film increased. The model achieved the highest accuracy of 0.981 with correctly aligned films, while the lowest accuracy of 0.937 was observed for films exhibiting severe misalignment of ± 15° (p < 0.001). The average time required for the tasks of image rotation and classification for each image was 0.17 s, which was significantly faster than that of the manual process, which required 1.2 s (p < 0.001). Conclusion This study demonstrated the potential of DL-based models in automating dental film mounting with high accuracy and efficiency. The proper alignment of X-ray films is crucial for accurate classification by the model.

Funder

Chang Gung Memorial Hospital, Linkou

National Taipei University of Technology

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3