The differential value of radiomics based on traditional T1-weighted sequences in newborns with hyperbilirubinemia

Author:

Sun Yan,Liao Yi,Jia Fenglin,Ning Gang,Wang Xinrong,Zhang Yujin,Li Pei,Qu Haibo

Abstract

Abstract Background On the basis of visual-dependent reading method, radiological recognition and assessment of neonatal hyperbilirubinemia (NH) or acute bilirubin encephalopathy (ABE) on conventional magnetic resonance imaging (MRI) sequences are challenging. Prior studies had shown that radiomics was possible to characterize ABE-induced intensity and morphological changes on MRI sequences, and it has emerged as a desirable and promising future in quantitative and objective MRI data extraction. To investigate the utility of radiomics based on T1-weighted sequences for identifying neonatal ABE in patients with hyperbilirubinemia and differentiating between those with NH and the normal controls. Methods A total of 88 patients with NH were enrolled, including 50 patients with ABE and 38 ABE-negative individuals, and 70 age-matched normal neonates were included as controls. All participants were divided into training and validation cohorts in a 7:3 ratio. Radiomics features extracted from the basal ganglia of T1-weighted sequences on magnetic resonance imaging were evaluated and selected to set up the prediction model using the K-nearest neighbour-based bagging algorithm. A receiver operating characteristic curve was plotted to assess the differentiating performance of the radiomics-based model. Results Four of 744 radiomics features were selected for the diagnostic model of ABE. The radiomics model yielded an area under the curve (AUC) of 0.81 and 0.82 in the training and test cohorts, with accuracy, precision, sensitivity, and specificity of 0.82, 0.80, 0.91, and 0.69 and 0.78, 0.8, 0.8, and 0.75, respectively. Six radiomics features were selected in this model to distinguish those with NH from the normal controls. The AUC for the training cohort was 0.97, with an accuracy of 0.92, a precision of 0.92, a sensitivity of 0.93, and a specificity of 0.90. The performance of the radiomics model was confirmed by testing the test cohort, and the AUC, accuracy, precision, sensitivity, and specificity were 0.97, 0.92, 0.96, 0.89, and 0.95, respectively. Conclusions The proposed radiomics model based on traditional TI-weighted sequences may be used effectively for identifying ABE and even differentiating patients with NH from the normal controls, which can provide microcosmic information beyond experience-dependent vision and potentially assist in clinical diagnosis and treatment.

Funder

The National Key Research and Development Program of China

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3