Diagnostic performance of biomarker S100B and guideline adherence in routine care of mild head trauma

Author:

Faisal Mohammed,Vedin TomasORCID,Edelhamre Marcus,Forberg Jakob Lundager

Abstract

Abstract Background The Scandinavian Neurotrauma Committee (SNC) has recommended the use of serum S100B as a biomarker for mild low-risk Traumatic brain injuries (TBI). This study aimed to assess the adherence to the SNC guidelines in clinical practice and the diagnostic performance of S100B in patients with TBI. The aims of this study were to examine adherence to the SNC guideline and the diagnostic accuracy of serum protein S100B. Methods Data of consecutive patients of 18 years and above who presented to the emergency department (ED) at Helsingborg Hospital with isolated head injuries, were retrieved from hospital records. Patients with multitrauma, follow-up visits, and visits managed by a nurse without physician involvement were excluded. Results A total of 1671 patients were included of which 93 (5.6%) had intracranial hemorrhage. CT scans were performed in 62% of patients. S100B was measured in 26% of patients and 30% of all measurements targeted the low-risk mild head injuries indicated by the guideline. S100B's recommended cut-off value (≥ 0.10 µg/L) had a 100% sensitivity, 47% specificity, 10.1% positive predictive value, and 100% negative predictive value—if applied to the target SNC category (SNC 4). If applied to all patients tested, the sensitivity was 93% for traumatic intracranial hemorrhage (TICH). Current ED practices were adherent to the SNC guideline in 55% of patients. Non-adherent practices occurred in 64% of patients with low-risk mild head injuries (SNC4) including overtesting or undertesting of S100B and CT scans. Conclusion Adherence to guidelines was low and associated with a higher admission rate than non-adherence practice but no significant increase in missed TICH or death associated with non-adherence to guideline was found. In routine care, we found that the sensitivity and NPV of serum protein S100B was excellent and safely ruled out TICH when measured in the patient category recommended by the guideline. However, measuring serum protein S100B in patients not recommended by the guideline rendered unacceptably low sensitivity with possible missed TICHs as a consequence. To further delineate the magnitude and impact of non-adherence, more studies are needed.

Funder

Lund University

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine,Emergency Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3