Surgical helmet systems in total joint arthroplasty: assessment of hood sterility and donning technique

Author:

McAleese TimothyORCID,Ó Doinn Tiarnán,Broderick James M.,Farrington Ross,Prior Anna-Rose,Quinlan John F.

Abstract

Abstract Background The incidence of prosthetic joint infection (PJI) is increasing, coincident with the rising volume of joint arthroplasty being performed. With recent controversy regarding the efficacy of surgical helmet systems (SHS) in preventing infection, the focus has turned to the correct donning techniques and usage of surgical hoods. The aim of this study was to compare the bacterial contamination of the operating surgeon’s gloves after two common donning techniques of SHS hoods. We also evaluated the baseline sterility of the SHS hoods at the beginning of the procedure. Methods The bacterial contamination rate was quantified using colony-forming units (CFUs), with 50 trials performed per donning technique. Samples were cultured on 5% Columbia blood agar in ambient air at 37 °C for 48 h and all subsequent bacterial growth was identified using a MALDI-TOF mass spectrometer. In Group 1, the operating surgeon donned their colleague’s hood. In Group 2, the operating surgeon had their hood applied by a non-scrubbed colleague. After each trial, the operating surgeon immediately inoculated their gloves onto an agar plate. The immediate sterility of 50 SHS hoods was assessed at two separate zones—the screen (Zone 1) and the neckline (Zone 2). Results There was no significant difference in contamination rates between the two techniques (3% vs. 2%, P = 0.99) or between right and left glove contamination rates. Immediately after donning, 6/50 (12%) of SHS hoods cultured an organism. Contamination rates at both the face shield and neckline zones were equivalent. The majority of bacteria cultured were Bacillus species. Discussion We found no significant difference in the operating surgeon’s glove contamination using two common SHS hood-donning techniques when they were performed under laminar airflow with late fan activation. We suggest the SHS hood should not be assumed to be completely sterile and that gloves are changed if it is touched intraoperatively.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3