Asymmetric gap balancing improves knee kinematic following primary total knee arthroplasty

Author:

Valpiana Pieralberto,Salvi Andrea Giordano,Ghirardelli Stefano,Bernardi Matteo,Petralia Giuseppe,Aloisi Giuseppe,Schaller Christian,Indelli Pier FrancescoORCID

Abstract

Abstract Purpose The purpose of this study was to demonstrate closer-to-normal knee kinematics following primary total knee arthroplasty (TKA) performed establishing asymmetric gap balancing intraoperatively. Material and method Two age-, sex-, BMI-matched groups of patients underwent medially stabilized TKA because of isolated knee disease. Group A (12 patients) underwent “unrestricted” kinematic alignment (uKA) according to Howell while group B (15 patients) received robot-assisted “simplified” KA (sKA) with an alignment goal (Hip-Knee-Ankle axis-HKA) ± 5° respect to the mechanical axis. Intraoperatively, in group B, the flexion gap at 90° was first set at an average of 1.5 mm (0–5 mm; SD 4.4 mm) tighter in the medial compartment with respect to the lateral; in the same way, the extension gap was then set at an average of 2.0 mm (0–4.5 mm; SD 3.1 mm) tighter in the medial compartment with respect to the lateral. All patients, including a non-arthritic cohort (group C: 5 controls) underwent gait analysis using an instrumented treadmill (WalkerView–WV) equipped with an instrumented belt armed with a 3D video camera. The WV software evaluated multiple spatiotemporal and kinematic parameters, including: (1) contact time (s); (2) knee ROM during gait cycle; (3) step length percentage with respect to total gait (%) and pure step length (cm). Statistical analyses included t-Test and ANOVA and were conducted by using SPSS. Results At the final FU, significant differences were noted during gait between the two TKA groups (uKA-sKA) and the controls. Both TKA groups showed superior mean contact time on the surgical knee (uKA 1 s; sKA 0.97 s) as compared to the controls (0.72 s) (P = 0.002) while no differences were found between them (P = 0.11). TKA groups showed a lower, maximum ROM in the surgical knee (mean uKA 36º; mean sKA 49º) relative to the controls (mean 57º) (P < 0.05) but a statistical difference was found between them (P = 0.003). Both TKA groups showed a higher step length percentage with respect to the total gait and a shorter step length on the surgical side (uKA: mean 8.28% and mean step length 35.5 cm; sKA: mean 8.38% and mean step length 34.6 cm) in comparison to the controls (mean 3.38%; mean step length 71.4 cm) (P < 0.05) while no statistical differences were found between them. Conclusion To our knowledge, this was the first study to exhibit the kinematic advantages of a slightly asymmetric gap balancing during KA TKA. Combining a medially-stabilized implant design and a surgical technique aiming to obtain a tighter medial compartment represents a promising approach to improve outcomes after TKA. Graphical Abstract

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3