Author:
Rioual Stephane,Lescop Benoit,Pellé Julien,de Alkmim Radicchi Gerusa,Chaumat Gilles,Bruni Marie-Dominique,Becker Johan,Thierry Dominique
Abstract
AbstractMonitoring of atmospheric pollutants is a key point for preventive conservation since these species are known to impact the integrity of many artifacts including metals, papers, pigment and textiles. The problem can be amplified in closed environments, like in exhibition rooms and showcases, where temperature and relative humidity gradients and levels can introduce additional micro-climatic problems. One objective of the EU-SensMat project concerns the development of low cost and low visual nuisance sensors sensitive to these pollutants, making them affordable for all museums including small ones. For this purpose, the Radio-Frequency Identification (RFID) technology was considered to produce air-quality sensors based on reactive metallic dosimeter. Besides the low cost, they can be easily integrated to other existing RFID applications such as identification tasks since the interrogation is made with a commercial UHF-RFID reader. The description and the main features of these sensors are discussed in this paper. Moreover, as it will be shown, the subsequent chemical analysis of the sensitive part of the sensors provide useful information to determine the origin of the pollutants.
Funder
European Union’s Horizon H2020 research and innovation program
Publisher
Springer Science and Business Media LLC
Subject
Archeology,Archeology,Conservation,Computer Science Applications,Materials Science (miscellaneous),Chemistry (miscellaneous),Spectroscopy
Reference40 articles.
1. Fish P, Muller C, Thickett D. An air quality standard for the protection of cultural heritage. Papyrus. 2014;15:26–9.
2. Grzywacz CM. Monitoring for gaseous pollutants in museum environments. Tools for conservation. Los Angeles: Getty Conservation Institute; 2006.
3. Krupinska B, Van Grieken R, De Wael K. Air quality monitoring in a museum for preventive conservation: results of a three-year study in the Plantin-Moretus Museum in Antwerp, Belgium. Microchem J. 2013;110:350–60. https://doi.org/10.1016/j.microc.2013.05.006.
4. Derek JP, Day DA, Pagonis D, Stark H, Handschy AV, Algrim LB, Miller SL, de Gouw JA, Ziemann PJ, Jimenez JL. Source of gas-phase species in an art museum from comprehensive real-time measurements. ACS Earth Space Chem. 2021;5:2267–552. https://doi.org/10.1021/acsearthspacechem.1c00229.
5. Ilies DC, Marcu F, Caciora T, Indrie L, Ilies A, Albu A, Costea M, Burt L, Baias S, Ilies M. Investigations of museum indoor microclimate and air quality. Case Study Romania Atmosphere. 2021;12:286. https://doi.org/10.3390/atmos12020286.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献