Abstract Background An automated tagging module (VISITAG™; Biosense Webster, Irvine, CA) allows objective demonstration of energy delivery. However, the effect of VISITAG™ on clinical outcomes remains unclear. This study evaluated (1) clinical outcome after AF ablation using VISITAG™ and (2) the prevalence of gaps in the ablation line. Methods This retrospective analysis included 157 consecutive patients (mean age, 56.7 years; 73.2% men) with paroxysmal atrial fibrillation who underwent successful PVI between 2013 and 2016. Outcomes after the index procedure were compared between those using the VISITAG™ module (VISITAG group, n = 62) and those not using it (control group, n = 95). The primary outcome was recurrence of AF or atrial tachycardia after a blanking period of 3 months. Results The VISITAG group showed significantly shorter overall procedure time (172.2 ± 37.6 min vs. 286.9 ± 66.7 min, P < 0.001), ablation time (49.8 ± 9.7 min vs. 82.8 ± 28.2 min, P < 0.001), and fluoroscopy time (11.8 ± 5.3 min vs. 34.2 ± 30.1 min, P < 0.001) compared with controls. The 1-year recurrence-free survival rate was not statistically different between the groups (70.8% in the VISITAG group vs. 79.2% in the control group, P = 0.189). Gaps in the VISITAG line were common in the both carina and left side pulmonary veins. Patients without gaps (≥ 5 mm) by the criteria emphasizing catheter stability (> 15 s, < 4 mm range, > 60% force over time, > 6 g contact force) showed higher recurrence-free survival rate compared with those with gaps (borderline statistical significance, 91.7% vs. 66.0%, P = 0.094). Conclusion Use of the VISITAG™ module significantly reduced procedure, ablation, and fluoroscopic times with a similar AF/AT recurrence rate compared with the conventional ablation. Clinical implications of minimizing gaps along the ablation line should be evaluated further in the future prospective studies.

Publisher

Springer Science and Business Media LLC

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3