Simulation of gymnastics performance based on MEMS sensor

Author:

Chen Bingxin,Kuang Lifei,He Wei

Abstract

AbstractThe development and progress of multi-sensor data fusion theory and methods have also laid the foundation for the research of human body posture tracking system based on inertial sensing. The main research in this paper is the simulation of gymnastics performance based on MEMS sensors. In the preprocessing to reduce noise interference, this paper mainly uses median filtering to remove signal glitches. This article uses virtual character models for gymnastics performances. The computer receives sensor data from the sink node of the motion capture device through a Bluetooth communication module. The unit calculates the quaternion output from the dynamic link library of sensor data processing, calculates the rotation amount and coordinate offset of each sensor node’s limb, and uses the character model to realize the real-time rendering of the virtual character model. At the same time, it controls the storage of sensor data, the drive of the model, and the display of the graphical interface. When a gesture action is about to occur, a trigger signal is given to the system to mark the beginning of the action, so as to obtain the initial data of each axis signal of the MEMS sensor. When the gesture action is completed, give the system a signal to end the action. Mark the end of the action, so that you can capture the original signal data during the beginning and end of the gesture action. In order to ensure the normal communication between PS and PL, it is necessary to test the key interfaces involved. Because the data received by the SPI acquisition module is irregular, it is impossible to verify whether the data is wrong, so the SPI acquisition module is replaced with a module that automatically increments data, and the IP core is generated, and a test platform is built for testing. The data shows that the average measurement error of X-axis displacement of the space tracking system is 8.17%, the average measurement error of Y-axis displacement is 7.51%, the average measurement error of Z-axis displacement is 9.72%, and the average error of three-dimensional space measurement is 8.7%. The results show that the MEMS sensor can accurately recognize the action with high accuracy.

Publisher

Springer Science and Business Media LLC

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. An 11.6aF/kPa Mechanical Stress Sensor With 0.808% Temperature-Drift Oscillator for Flip-Chip Packaging;IEEE Transactions on Circuits and Systems II: Express Briefs;2023-02

2. Analysis of full-body motion capture system design based on ultra wide band technology;International Conference on Computer Vision and Pattern Analysis (ICCPA 2021);2022-03-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3