Influencing factors comparing different vault groups after phakic implantable collamer lens implantation: review and meta-analysis

Author:

Zhang Pengcheng,Guo Chenjun,Wang Song,Jiang Wenshan,Wang Dan,Yan Hong

Abstract

Abstract Background Studies on the factors affecting vault after posterior chamber phakic Implantable Collamer Lens (ICL) have been carried out, but most of them are single-centered and subjective selections of parameters. The present study aimed to systematically analyze the factors for vault. Methods A systematic review of case series, case-control, and cohort studies derived from the articles published in PubMed, the Cochrane Library, Embase, Web of Science, CNKI, CBM, Wanfang and VIP, as well as ClinicalTrials, which were conducted to search for studies on factors of vault using four core terms: phakic intraocular lenses, vault, risk factor and observational study, from January 01, 1997, to February 20, 2023. The included studies were meta-analyzed quantitatively and described qualitatively. Subsequently, meta-regression and subgroup analysis were used. Results We identified 13 studies (1,607 subjects), and 14 factors were considered. Meta-analysis showed that anterior chamber depth (ACD), horizontal corneal white-to-white (hWTW), ICL-size, and age are dual effects of the abnormal vaults; anterior chamber volume (ACV) and lens thickness (LT) are a one-way effect; while axial length (AL), ICL- spherical equivalent (ICL-SE) and Km are insignificant. In addition, descriptive analysis of anterior chamber angle (ACA), horizontal sulcus to sulcus (hSTS), ciliary processes height (T value), crystalline lens rise (CLR), and gender showed that all factors except gender tend to have significant effects on vault. Sensitivity analysis showed stable combined results. Country and design respectively affect the heterogeneity in ACD and ICL-size at low vault, while design affects the heterogeneity in ACD at high vault. No publication bias exists. Conclusions Vault after ICL is related to multiple factors, especially anterior segmental biologic parameters, and they are weighted differently. We hope to provide a reference for the selection and adjustment of ICL.

Funder

Xi’an Talent Program, China

Publisher

Springer Science and Business Media LLC

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3