Corneal biomechanical characteristics following small incision lenticule extraction for myopia and astigmatism with 3 different cap thicknesses

Author:

Lv Xiaotong,Zhang Fengju,Song Yanzheng,Zhai Changbin,Guo Ning,Lai Lingbo,Xu Yushan

Abstract

Abstract Background The design of cap thickness for small incision lenticule extraction (SMILE) plays a role in post-laser vision correction (post-LVC) corneal biomechanics. This study aimed to compare the corneal biomechanical characteristics following SMILE with different cap thicknesses of 110 μm, 120 μm, and 130 μm for myopia and myopic astigmatism correction. Methods Seventy-five patients (146 eyes) who underwent SMILE with designed cap thickness of 110 μm, 120 μm, and 130 μm were recruited at the Eye Center of Beijing Tongren Hospital between August 2020 and November 2021. Visual acuity, refraction, and corneal biomechanical parameters were measured preoperatively, 1 week and 1, 3, 6 months postoperatively. One-way analysis of variances (ANOVA) with Bonferroni correction or Kruskal-Wallis test was performed to compare the parameters among different groups. Repeated-measures analysis of variance with Bonferroni correction or Friedman test was applied for comparing the parameters within different follow-up times. Results Uncorrected distance visual acuity of 110-μm group was better only at 1-week and 1-month postoperatively (P = 0.012, 0.037). There were no significant differences in spherical equivalent, nor in Corvis biomechanical index-laser vision correction (CBI-LVC). All the parameters reached stability at 3-month postoperatively. Integrated radius (IR) and deformation amplitude ratio 2 mm (DA ratio 2 mm) in 120-μm and 130-μm groups were higher than 110-μm group at 1-month postoperatively (P = 0.019, 0.002). So was Ambrósio relational thickness (ARTh) at 6-month postoperatively (P = 0.011). Stiffness parameter at applanation A1 (SP-A1), stress-strain index (SSI), biomechanically corrected intraocular pressure (bIOP) and central corneal thickness (CCT) were highest in 130-μm group, followed by 120-μm group, then 110-μm group at 3-month (P<0.001, P = 0.030, P = 0.027, P = 0.008) and 6-month (P<0.001, P = 0.002, P = 0.0023, P = 0.001) postoperatively. Conclusions The corneal stiffness following SMILE was greatest with 130-μm cap, followed by 120-μm cap, then 110-μm cap. 130-μm cap might have advantages in terms of corneal biomechanics and retreatment option. The SMILE-designed protocol should be customized in practice.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3