Microstructural and microperimetric comparison of internal limiting membrane peeling and insertion in large idiopathic macular hole

Author:

Liu Lingzi,Wang Zengyi,Yu Yanping,Yang Xiaohan,Qi Biying,Zhang Ke,Liu WuORCID

Abstract

Abstract Background The internal limiting membrane (ILM) insertion technique was widely used to treat large macular hole (MH) for the high closure rate. However, the prognosis of closed MH after ILM insertion compared to ILM peeling remains controversial. This study aimed to compare foveal microstructure and microperimeter in large idiopathic MH surgically closed by ILM peeling and ILM insertion. Methods This retrospective, non-randomized, comparative study included patients with idiopathic MH (minimum diameter ≥ 650 μm) who underwent primary pars plana vitrectomy (PPV) with ILM peeling or ILM insertion. The initial closure rate was recorded. Patients with initially closed MHs were divided into two groups according to the surgery methods. The best-corrected visual acuity (BCVA), optical coherence tomography (OCT) and microperimeter-3 (MP-3) outcomes of two groups were compared at baseline, 1 and 4 months postoperatively. Results For idiopathic MH (minimum diameter ≥ 650 μm), ILM insertion had a significantly higher initial closure rate than ILM peeling (71.19% vs. 97.62%, P = 0.001). Among 39 patients with initially closed MHs who were on regular follow-up, twenty-one were assigned to the ILM peeling group and 18 to the ILM insertion group. Postoperative BCVA improved significantly in both groups. The final BCVA (logMAR) (0.40 vs. 0.88, P < 0.001), macular hole sensitivity (19.66 dB vs. 14.14 dB, P < 0.001), peripheral sensitivity of macular hole (24.63 dB vs. 21.95 dB, P = 0.005), and fixation stability (FS) within 2 degrees (82.42% vs. 70.57%, P = 0.031) were significantly better and external limiting membrane (ELM) defect (330.14 μm vs. 788.28 μm, P < 0.001) and ellipsoid zone (EZ) defect (746.95 μm vs. 1105.11 μm, P = 0.010) were significantly smaller in the ILM peeling group than in the ILM insertion group. Conclusion For initially closed MHs (minimum diameter ≥ 650 μm), both ILM peeling and ILM insertion significantly improved the microstructure and microperimeter in the fovea. However, ILM insertion was less efficient at microstructural and functional recovery after surgery.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3