Background
To compare the surgical outcomes of the inverted internal limiting membrane (ILM) flap technique and ILM insertion for macular hole (MH) without retinal detachment in eyes with extremely high myopia.
Methods
In this retrospective study, we analyzed 22 eyes with an axial length ≥ 30.0 mm that had underwent MH surgery between April 2015 and August 2021. The surgical procedures involved either an inverted ILM flap or ILM insertion. The outcomes were compared between the two techniques. Closure of the MH was confirmed by optical coherence tomography (OCT). The best-corrected visual acuity (BCVA) was measured before and after surgery. Associated complications were documented.
Results
The median of axial length was 30.64 mm (range, 30.0-34.42). The MH closed in 100% (22/22) eyes and did not recur with a median follow-up of 12.5 months. For the inverted ILM flap technique, the median BCVA improved significantly from 0.80 logarithm of the minimum angle of resolution (logMAR) (range, 0.40-2.00) before surgery to 0.70 logMAR (range, 0.09–1.52) after surgery (p = 0.002). In addition, the median of final BCVA was better for the inverted ILM flap than ILM insertion (0.7 logMAR V.S. 1.00 logMAR; p = 0.016).
Conclusions
In eyes with extremely high myopia, despite comparable effects on MH closure for both ILM insertion and the inverted ILM flap, the later technique achieved significantly better visual outcomes.