Influence of measurement differences of anterior chamber depth and axial length on lens thickness evaluation in cataract patients: a comparison of two tests

Author:

Xu Jiayi,Li Chen,Wang Lijun,Li Caixin,Li Xin,Lu PeirongORCID

Abstract

Abstract Background The purpose of this study was to investigate the agreement of lens thickness (LT) measurements made by contact A-scan ultrasonography and Lenstar LS900 as well as the influence of anterior chamber depth (ACD) and axial length (AL) measurement differences on LT measurement in cataract patients in the two techniques. Methods 1247 cataract patients (1247 eyes) participated in this retrospective cross-sectional study. Ocular biometric measurements were performed with Lenstar LS900 and A-scan ultrasonography respectively, and the measured results of AL, ACD and LT were compared using Pearson correlation coefficients (r) and Bland-Altman analyses. Results Bland-Altman analyses showed poor agreement between the A-scan ultrasonography and Lenstar LS900 in measuring AL and ACD. The average difference of LT was 0.01 mm; the consistency limit was − 0.86 mm, 0.88 mm; and 95.27% of datapoints were within the 95% consistency limit. The consistency of LT measurements between the two techniques was poor for those subjects whose ACD or AL values were beyond the 95% consistency limit. Among the subjects whose AL or ACD values measured by A-scan ultrasonography were greater than those measured by Lenstar LS900, 93.33% of them were within the 95% consistency limit, suggesting that the consistency of LT measurement between the two techniques was poor. Of patients whose ACD or AL measured by A-scan ultrasonography were smaller than that of Lenstar LS900, 96.01% of them were within the 95% consistency limit. Conclusions There was good agreement of the LT measurements between A-scan ultrasonography and Lenstar LS900, except for the axis deviating from the apparent axis during A-scan ultrasonography. If this error can be avoided, A-scan ultrasonography can replace Lenstar LS900 in LT measurement in cataract patients.

Funder

Jiangsu Provincial Medical Innovation Team

Soochow Scholar Project of Soochow University

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3