Transscleral vs endoscopic cyclophotocoagulation: safety and efficacy when combined with phacoemulsification

Author:

Nirappel Abraham,Klug Emma,Neeson Cameron,Chachanidze Mari,El Helwe Hani,Hall Nathan,Chang Ta C.,Shen Lucy Q.,Solá-Del Valle David

Abstract

Abstract Purpose To compare the effectiveness and safety of phacoemulsification combined with endoscopic cyclophotocoagulation (phaco/ECP), phacoemulsification combined with MicroPulse transscleral cyclophotocoagulation (phaco/MP-TSCPC), and phacoemulsification alone (phaco) in the treatment of coexisting cataract and glaucoma. Methods Retrospective cohort study of consecutive cases at Massachusetts Eye & Ear. The main outcome measures were the cumulative probabilities of failure between the phaco/ECP group, phaco/MP-TSCPC group, and the phaco alone group with failure defined as reaching NLP vision at any point postoperatively, undergoing additional glaucoma surgery, or the inability to maintain ≥ 20% IOP reduction from baseline with IOP between 5–18 mmHg while maintaining ≤ baseline medications. Additional outcome measures included changes in average IOP, number of glaucoma medications, and complication rates. Results Sixty-four eyes from 64 patients (25 phaco/ECP, 20 phaco/MPTSCPC, 19 phaco alone) were included in this study. The groups did not differ in age (mean 71.04 ± 6.7 years) or length of follow-up time. Baseline IOPs were significantly different between groups (15.78 ± 4.7 mmHg phaco/ECP, 18.37 ± 4.6 mmHg phaco/MP-TSCPC, 14.30 ± 4.2 mmHg phaco alone, p = 0.02). Primary open-angle glaucoma was the most common type of glaucoma in the phaco alone (42%) and phaco/ECP (48%) groups while mixed-mechanism glaucoma was the most common type in the phaco/MP-TSCPC group (40%). Surgical failure was less likely in eyes in the phaco/MP-TSCPC (3.40 times, p = 0.005) and phaco/ECP (1.40 times, p = 0.044) groups compared to phaco alone based on the Kaplan–Meier survival criteria. These differences maintained statistical significance when differences in preoperative IOP were taken into account using the Cox PH model (p = 0.011 and p = 0.004, respectively). Additionally, surgical failure was 1.98 times less likely following phaco/MP-TSCPC compared to phaco/ECP (p = 0.038). This difference only approached significance once differences in preoperative IOP were accounted for (p = 0.052). There was no significant difference in IOP reduction at 1 year between groups. Mean IOP reductions at 1 year were 3.07 ± 5.3 mmHg from a baseline of 15.78 ± 4.7 in the phaco/ECP group, 6.0 ± 4.3 mmHg from a baseline of 18.37 ± 4.6 in the phaco/MP-TSCPC group and 1.0 ± 1.6 from a baseline of 14.30 ± 4.2 mmHg in the phaco alone group. There were no differences in complication rates among the three groups. Conclusions Both Phaco/MP-TSCPC and phaco/ECP appear to provide superior efficacy for IOP control when compared to phaco alone. All three procedures had similar safety profiles.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3