The impact of irregular corneal shape parameters on visual acuity and contrast sensitivity

Author:

Liduma Sanita,Luguzis Artis,Krumina Gunta

Abstract

Abstract Background To understand which irregular corneal parameters determine the visual quality in keratoconus subjects. Methods The cross-sectional study examined the eyes of 44 subjects, graded from the first to third keratoconus stages by Amsler-Krumeich classification. We obtained measurements in two ways: (a) by projecting two perpendicular axes onto a cornea (first, through the central point of the cornea and keratoconus apex; second, as the perpendicular axis) to read the elevation values at points on these axes as parameters characterising the corneal surface; (b) by projecting circles with different diameters around the central part of the cornea (1, 2, and 3 mm) and reading elevation values at points equally displaced on these circles as parameters characterising an anterior surface slope. Irregular corneal shape parameters’ correlations with visual acuity and contrast sensitivity were determined in order to understand which corneal slope parameter has the strongest correlation with visual acuity and contrast sensitivity. Results Parameters characterising the corneal surface’s correlations with contrast sensitivity were from r = 0.25 (p = 0.03) at 3 cpd to r = 0.47 (p < 0.01) at 9 cpd for the highest elevation and from r = 0.33 (p = 0.09) at 5 cpd to r = 0.40 (p < 0.01) at 11 cpd for the lowest elevation in all subjects together, while for visual acuity the parameters were r = 0.30 (p < 0.01) for the highest elevation and r = 0.21 (p = 0.06) for the lowest elevation in all subjects together. The correlation between contrast sensitivity and the highest and lowest corneal point in all measured cornea was stronger for subjects with a peripheral corneal apex than for those with a central apex. In keratoconus subjects, contrast sensitivity displayed a strong correlation with slope in the central part of the cornea (with a radius of 1 mm) ranging from 0.48 (p < 0.01) at 3 cpd to 0.61 (p < 0.01) at 9 cpd. Conclusion Contrast sensitivity has a higher correlation with corneal shape parameters than with visual acuity. Subjects with a peripheral corneal apex had stronger correlations with visual acuity and contrast sensitivity than did subjects with a central apex. In keratoconus subjects, the strongest correlation was for contrast sensitivity and elevation (slope) in the region within a 1 mm radius of the corneal centre in the opposite direction of the keratoconus apex (direction (ax) CB).

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3