Abstract
AbstractPurposeTo evaluate corneal densitometry after allogeneic corneal small-incision intrastromal lenticule implantation (SILI) for hyperopia.MethodsA retrospective study. Thirty-one hyperopic eyes of 24 patients who underwent SILI were enrolled in this study. Examinations took place preoperatively and 1 week, 1 month, 3 months, and 6 months postoperatively. Corneal densitometry (CD) from different concentric radial zones (0–2, 2–6, and 6–10 mm annulus) and layers (anterior, central, and posterior) were obtained using Scheimpflug imaging. The association between CD changes and the uncorrected distance visual acuity (UDVA), spherical equivalent (SE), central corneal thickness (CCT) and K value were examined.ResultsNo serious intraoperative complications occurred during SILI. The mean total CD increased postoperatively compared to preoperatively (P < 0.01). However, no significant differences were found among the four subsequent follow-up time points (P > 0.05). At 6 months postoperatively, the CD values showed an increase of 2.71 ± 2.52, 2.23 ± 2.25, and 1.87 ± 2.46 at the 0–2, 2–6, and 6–10 mm annuli, respectively (all atP < 0.01). The anterior 120 μm displayed the highest densitometry before and after surgery (all atP < 0.01). No significant increase was found within the posterior 60 μm of the cornea (P > 0.05). No correlation was found between the CD and relevant parameters(all atP > 0.05).ConclusionsSILI resulted in an increase in CD within the surgically altered area, however such change has no significant correlation with visual outcomes.
Funder
Open Program of Jinan Mingshui Eye Hospital
National Natural Science Foundation of China
Publisher
Springer Science and Business Media LLC
Subject
Ophthalmology,General Medicine
Reference23 articles.
1. Sun L, Yao P, Li M, et al. The safety and predictability of implanting autologous lenticule obtained by SMILE for hyperopia. J Refract Surg. 2015;31:374–9.
2. Jacob S, Kumar DA, Agarwal A, et al. Preliminary evidence of successful near vision enhancement with a new technique: presbyopic allogenic refractive lenticule (PEARL) corneal inlay using a SMILE lenticule. J Refract Surg. 2017;33:224–9.
3. Mastropasqua L, Nubile M, Salgari N. Femtosecond laser-assisted stromal lenticule addition keratoplasty for the treatment of advanced keratoconus: a preliminary study. J Refract Surg. 2018;34:36–44.
4. Moshirfar M, Shah TJ, Masud M, et al. A modified small-incision Lenticule Intrastromal Keratoplasty (sLIKE) for the correction of high hyperopia: a description of a new surgical technique and comparison to Lenticule Intrastromal Keratoplasty (LIKE). Med Hypothesis Discov Innov Ophthalmol. 2018;7:48–56.
5. Pradhan KR, Reinstein DZ, Carp GI, et al. Femtosecond laser-assisted keyhole endokeratophakia: correction of hyperopia by implantation of an allogeneic lenticule obtained by SMILE from a myopic donor. J Refract Surg. 2013;29:777–82.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献