The new future perspective in corneal tissue utilisation – methods of preparation and preservation

Author:

Polachova MartinaORCID,Netukova Magdalena,Benada Oldrich,Kucera Tomas,Kolin Vojtech,Baxant Alina-Dana,Sirolova Zuzana,Studeny Pavel

Abstract

Abstract Purpose The goal of our study is to find an optimal approach to the preparation and preservation of corneal stromal tissue. We want to compare different methods of corneal stromal tissue creation and storage to optimize the efficacy of this process under the conditions of an eye bank. After we find the most suitable method to create a safe high quality product, we want to prove the possibility of using a single donor cornea for more than one patient. We would also like to verify the feasibility of making more corneal lenticules after the removal of a corneal endothelium for DMEK transplantation. Methods We provided morphological (histology, scanning electron microscope) and microbiological analysis in order to compare different methods of corneal lenticule and corneal stromal lamellae preparation and preservation. We also tested the surgical handling of the tissue to secure a safe manipulation of the tissue for clinical use. We compared two methods of corneal lenticule preparation: microkeratome dissection and femtosecond laser. As methods of preservation, we tested hypothermia, cryopreservation at -80 degrees Celsius in DMSO (dimethyl sulfoxide) and storage at room temperature with glycerol. Some intrastromal lenticules and lamellae in each group were previously irradiated with gamma radiation of 25 kGy (KiloGray). Results Corneal stromal lamellae prepared with a microkeratome have a smoother cut – side surface compared to lamellae prepared with a femtosecond laser. Femtosecond laser preparation caused more irregularities on the surface and we detected more conglomerates of the fibrils, while lamellae made with microkeratome had more sparse network. Using femtosecond laser, we were able to make more than five lenticules from a single donor cornea. Gamma irradiation led to damage of collagen fibrils in corneal stroma and a loss of their regular arrangement. Corneal tissue stored in glycerol showed collagen fibril aggregates and empty spaces between fibrils caused by dehydration. Cryopreserved tissue without previous gamma irradiation showed the most regular structure of the fibrils comparable to storage in hypothermia. Conclusion Our results suggest that formation of a corneal lenticule lamellae by microkeratome results in smoother corneal lenticules, while being much cheaper than formation by femtosecond laser. Gamma irradiation of 25 kGy caused damage of the collagen fibres as well as their network arrangement, which correlated with loss of transparency and stiffer structure. These changes impair possible surgical utilisation of gamma irradiated corneas. Storage in glycerol at room temperature and cryopreservation had similar outcomes and we believe that both methods are appropriate and safe for further clinical use .

Funder

Grantová Agentura, Univerzita Karlova

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3