Diode laser transscleral cyclophotocoagulation causes intraocular collamer lens displacement in pseudophakic eye: a case report

Author:

Wei Wei,Yu Xueqing,Yang Lu,Xiong Chan,Zhang Xu

Abstract

Abstract Background With the rapid development of intraocular collamer lens (ICL) operation, it is foreseeable that we will encounter a large number of glaucoma patients with ICL implantation history. However, our current understanding of the treatment of glaucoma patients with ICL is limited. Hence we report a rare case of refractory glaucoma after intraocular collamer lens and intraocular lens implantation in a patient who underwent unsuccessful transscleral cyclophotocoagulation, which led to intraocular collamer lens displacement, angle closure and uncontrolled intraocular pressure. Case presentation A 39-year-old woman presented with intractably elevated intraocular pressure in the right eye. Since her intraocular collamer lens implantation surgery in 2017, her intraocular pressure had remained over 40 mmHg while using 3 types of anti-glaucoma medications. The patient had a history of phacoemulsification and posterior chamber phakic intraocular lens implantation for complicated cataracts secondary to uveitis in 2006. On gonioscope examination, there were signs of pigment dispersion, and the anterior chamber angle was open. Ultrasound biomicroscopy examination showed contact and rubbing between the intraocular collamer lens and posterior surface of the iris. And typical advanced glaucomatous optic neuropathy and visual field defects were observed. Transscleral cyclophotocoagulation was performed to control the intraocular pressure and prevent further visual field loss. However, the intraocular collamer lens was displaced after transscleral cyclophotocoagulation, which resulted in formation of a shallow anterior chamber 1 week later, angle closure and loss of intraocular pressure control 1 month later, even though the maximum dose of anti-glaucoma medication was used. Finally, an Ahmed glaucoma valve was successfully implanted in her anterior chamber, and the glaucoma was controlled, as observed at the 10-month follow-up. Conclusions Pigment dispersion is a common phenomenon after intraocular collamer lens implantation and may accelerate the progression of glaucoma. Transscleral cyclophotocoagulation should be carefully considered in glaucoma patients with elevated intraocular pressure after intraocular collamer lens implantation, given that transscleral cyclophotocoagulation may cause intraocular collamer lens displacement.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3