Measuring impact of a quality improvement initiative on glaucoma clinic flow using an automated real-time locating system

Author:

Musser John A.,Cho Juno,Cohn Amy,Niziol Leslie M.,Ballouz Dena,Burke David T.,Newman-Casey Paula Anne

Abstract

Abstract Background Lean methodology helps maximize value by reducing waste, first by defining what value and waste are in a system. In ophthalmology clinics, value is determined by the number of patients flowing through the clinic for a given time. We aimed to increase value using a lean-methodology guided policy change, then assessed its impact on clinic flow using an automated radiofrequency identification (RFID) based real-time locating system (RTLS). Methods A total of 6813 clinical visits occurred at a single academic institution’s outpatient glaucoma clinic between January 5, 2018 to July 3, 2018. Over that period, 1589 patients comprising 1972 (29%) of visits were enrolled, with 1031 clinical visits occurring before and 941 visits after a policy change. The original policy was to refract all patients that improved with pinhole testing. The policy change was not to refract patients with a visual acuity ≥20/30 unless a specific request was made by the patient. Pre-post analysis of an automated time-motion study was conducted for the data collected 3 months before and 3 months after the policy change occurred on March 30, 2018. Changes to process and wait times were summarized using descriptive statistics and fitted to linear mixed regression models adjusting for appointment type, clinic volume, and daily clinic trends. Results One thousand nine hundred twenty-three visits with 1588 patients were included in the analysis. Mean [SD] age was 65.9 [14.7] years and 892 [56.2%] were women. After the policy change, technician process time decreased by 2.9 min (p < 0.0001) while daily clinical patient volume increased from 51.9 ± 16.8 patients to 58.4 ± 17.4 patients (p < 0.038). No significant difference was found in total wait time (p = 0.18) or total visit time (p = 0.83). Conclusions Real-time locating systems are effective at capturing clinical flow data and assessing clinical practice change initiatives. The refraction policy change was associated with reduced technician process time and overall the clinic was able to care for 7 more patients per day without significantly increasing patient wait time.

Funder

National Center for Advancing Translational Sciences

MCubed, University of Michigan

Research to Prevent Blindness

National Eye Institute

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Reference31 articles.

1. Cusumano MA. Manufacturing innovation: lessons from the Japanese auto industry. Sloan Manag Rev. 1988;30(1):29.

2. Poksinska B. The current state of lean implementation in health care: literature review. Qual Manag Health Care. 2010;19(4):319–29.

3. Ciulla TA, Tatikonda MV, ElMaraghi YA, et al. Lean six sigma techniques to improve ophthalmology clinic efficiency. Retina. 2018;38(9):1688–98.

4. Hribar MR, Biermann D, Read-Brown S, et al. Clinic workflow simulations using secondary EHR data. Paper presented at: AMIA Annual Symposium Proceedings 2016.

5. Patton MW Jr. Developing a time and motion study for a lean healthcare environment; 2011.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3