Clinical observation of phacoemulsification under the low perfusion pattern and low negative pressure in patients with low corneal endothelial cell density

Author:

Lin Yan,Zhou Biting,Yao Yihua,Ye Qin,Zhu Yihua,Wang Xiaohui

Abstract

Abstract Background To observe the safety and effect of phacoemulsification combined with intraocular lens (IOL) implantation in patients with low corneal endothelial cell density (CD) under the low perfusion pattern with low negative pressure. Methods In this retrospective case series study, a total of 16 patients (17 eyes) were studied. They had all been diagnosed with low corneal endothelial (CD) and cataracts in the First Affiliated Hospital of Fujian Medical University from December 2019 to October 2021. They underwent phacoemulsification combined with IOL implantation under the low perfusion pattern with low negative pressure. The variations of corneal endothelial( CD), coefficient of variation (CV) of the cell area, central corneal thickness (CCT), visual acuity, and intraocular pressure before and after the operation were observed and assessed. Then a paired t-test, repeated measures analysis of variance, and Pearson correlation analysis were adopted for data analysis. Results The mean intraocular pressure of the 17 eyes was 16.88 ± 6.47 mmHg before the operation and 14.41 ± 3.10 mmHg after the operation, showing a statistically significant difference of t = 2.222, and p = 0.041. Before the operation, the mean visual acuity was 0.16 ± 0.09, and after the operation, it was 0.45 ± 0.16, displaying a statistically significant difference of t = -9.917, p < 0.001. Before and after the operation, four of the 17 eyes had no detectable CD. The mean CD of the other 13 eyes at one month after the operation (644.308 ± 106.24 cells/mm2) was lower than that before the operation (709.62 ± 119.19 cells/mm2), and the differences were statistically significant (F = 20.044, p < 0.001). However, no statistically significant differences were found in the mean CV before the operation (31.23 ± 4.21), and at one month after the operation (32.62 ± 3.80; F = 2.130, p = 0.157). Moreover, the mean CCT of 14 eyes at one month after the operation (562.72 ± 27.82 μm) was larger than that before the operation (534.79 ± 24.69 μm). Conclusions The low perfusion pattern with low negative pressure is safe and effective for corneal endothelial dysfunction patients complicated with cataracts.

Funder

Qihang Funds of Fujian Medical University

Science and Technology Innovation joint Fund Project of Fujian Provincial Department of Science and Technology

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. EVA NEXUS-Phaco performance study;International Journal of Ophthalmology;2024-08-18

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3