Abstract
Abstract
Background
To compare the intraocular scattering before and after implantation of implantable collamer lens (ICL) V4c for correction of high myopia in a short term.
Methods
In this study, 38 eyes of 19 patients who underwent the implantation of ICL V4c were followed up for 3 months. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), objective scattering index (OSI), modulation transfer function cutoff frequency (MTF cutoff), strehl ratio (S/R), OV100%, OV20% and OV9% were measured pre- and postoperatively. Meantime, the Pseudophakic Dysphotopsia Questionnaire (PDQ) was scored to evaluate the subjective satisfaction of intraocular scattering pre- and postoperatively.
Results
The UCVA were − 0.02 ± 0.06, − 0.03 ± 0.07 and − 0.04 ± 0.07 logMAR at 1 week, 1 month and 3 months postoperatively which were significantly better than those preoperatively (P < 0.05). The BCVA were − 0.09 ± 0.09, − 0.09 ± 0.1 and − 0.1 ± 0.11 logMAR at 1 week, 1 month and 3 months after surgery, which were better than those before surgery significantly (t = 15.64, P < 0.05). The mean OSI were 2.37 ± 1.6, 1.63 ± 0.94, 1.5 ± 0.86 and 1.43 ± 1.05 preoperatively, 1 week, 1 month and 3 months postoperatively which was found significant difference (F = 12.92 P < 0.05). No significant differences were found in MTF cut off (F = 0.61, P = 0.62), S/R (F = 0.58, P = 0.36), OV100% (F = 0.966, P = 0.65), OV20% (F = 0.121, P = 0.96) and OV9% (F = 1.01, P = 0.30) between pre- and postoperatively. The PDQ results indicated that intraocular scattering reduced at 3 months after surgery significantly (P < 0.05).
Conclusions
The ICL V4c implantation for correcting high myopia induced less intraocular scattering and visual disorder than spectacle correction.
Publisher
Springer Science and Business Media LLC
Subject
Ophthalmology,General Medicine
Reference39 articles.
1. Sanders D. Implantable contact Lens in treatment of myopia study group. US Food and Drug Administration clinical trial of the implantable contact lens for moderate to high myopia. Ophthalmology. 2003;110:255–66.
2. Bloomenstein MR, Dulaney DD, Barnet RW, Perkins SA. Posterior chamber phakic intraocular lens for moderate myopia and hyperopia. Optometry (St Louis, Mo). 2002;73:435–46.
3. Rizk IM, Al-hessy A-AA, El-Khouly SE, Sewelam AM. Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia. Int J Ophthalmol. 2019;12:284.
4. Roberto Pineda I, Chauhan T. Phakic intraocular lenses and their special indications. J Ophthalmic Vision Res. 2016;11:422.
5. Saad A, Saab M, Gatinel D. Repeatability of measurements with a double-pass system. J Cataract Refract Surg. 2010;36:28–33.