Effects of tilt and decentration of Visian Implantable Collamer Lens (ICL V4c) on visual quality: an observational study

Author:

Niu Lingling,Zhang Zhe,Miao Huamao,Zhao Jing,Li Meiyan,He Ji C.,Yao Peijun,Zhou Xingtao

Abstract

Abstract Background The central hole of the Visian Implantable Collamer Lens (ICL V4c) provides a reference to observe its tilt or decentration. This study aimed to investigate the tilt and decentration effects of ICL V4c on visual quality after implantation. Methods A total of 135 eyes from 69 patients who underwent ICL V4c implantation were included in this study. Evaluation of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and aberrations were performed 6-months postoperatively. The anterior segment parameters were collected using CASIA2 anterior segment-optical coherence tomography, tilt and decentration of ICL V4c were analyzed using MATLAB software. All patients received questionnaires to investigate the visual quality postoperatively. Results The safety and effectiveness were 1.18 ± 0.17 and 1.11 ± 0.18, respectively. No significant changes were observed regarding higher-order and spherical aberrations after the operation; however, coma and trefoil significantly increased compared to preoperative values. The average total decentration and tilt was 0.21 ± 0.12 mm and 2.54 ± 1.00°, respectively. Horizontal, vertical, and total values of tilt and decentration were not significantly associated with postoperative CDVA, UDVA, and aberrations. The most common visual symptom was halo, and 97.04% of patients had a satisfaction score ≥ 8. The total or horizontal tilt was significantly positively correlated with the frequency, severity, and bothersome scores from the questionnaires. Conclusions ICL V4c implantation can obtain high visual quality and patient satisfaction. Although the degree of tilt and decentration after ICL V4c implantation was small, a positive effect on subjective visual quality was observed.

Funder

Research Project Grant of Shanghai Municipal Health Commission

National Natural Science Foundation of China

Project of Shanghai Science and Technology

Joint research project of new frontier technology in municipal hospitals

Clinical Research Plan of SHDC

Project of Shanghai Xuhui District Science and Technology

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3