The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500

Author:

Zhang Di,Yang Meng,Liu Ziyuan,Cai Hongyuan,Chen Xiaoyong,Zhang Chun

Abstract

Abstract Background To investigate the possible effect of implantable collamer lens (ICL) V4c on ocular biometric measurements by a new biometer Pentacam-AXL and partial coherence interferometry (PCI)-based IOLMaster 500 and intraocular lens power calculation using fourth-generation formula. Methods We retrospectively enrolled patients who underwent ICL (EVO-V4c, STAAR Surgical Co. Nidau, Switzerland) implantation surgery from September 2020 to November 2021. The Pentacam-AXL and IOLMaster 500 biometers were used to measure axial length (AL), anterior chamber depth (ACD), keratometry (K), white to white (WTW), and central corneal thickness (CCT) values before and at least 2 months after ICL V4c implantation. The IOL power was calculated using the Barrett Universal II formula. Results The study included 45 eyes in 28 patients. There was a significant increase in ALs (average 0.03 ± 0.07 mm, p = 0.01) and a significant decrease of ACDs (average 0.19 ± 0.17 mm, p < 0.001) based on Pentacam-AXL. Similar changes in ALs and ACDs were also found in IOLMaster 500. In addition, the difference in WTWs in the two devices and that of CCTs in Pentacam-AXL were statistically significant. However, the preoperative and postoperative K1 and K2 were separately comparable using either device. The IOL power calculated by the Barrett Universal II formula did not change significantly either by the software built in Pentacam-AXL or by manually putting the parameters of the IOLMaster 500 into the formula manually (p = 0.058, p = 0.675, respectively). Conclusions Ocular parameters including ALs, ACDs, WTWs, and CCTs using a new Pentacam-AXL and standard PCI-based IOLMaster 500 changed significantly before and after the ICL V4c implantation, while IOL power prediction using the Barrett Universal II formula was little affected.

Funder

Beijing Haidian Innovation and Transformation Project

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3