Periphery kinetic perimetry: clinically feasible to complement central static perimetry

Author:

Ma Xiaoxiao,Tang Li,Chen Xiaoming,Zeng Liuzhi

Abstract

Abstract Background Existing evidence suggests that visual field defect in eyes with glaucoma significantly varies between individuals. The following study compared the central visual field defects with the peripheral visual field defects in patients with suspect glaucoma and primary open-angle glaucoma (POAG) and investigated whether using the central visual field test alone could result in loss of clinically valuable information. Methods In this prospective observational study, 167 eyes from 89 patients with suspect glaucoma or POAG were first examined with static automated perimetry (SAP), followed by a peripheral visual field test on Octopus 900 perimeter (Haag-Streit, Koeniz, Switzerland). The peripheral visual field test was performed by “Auto Kinetic Perimetry” program, in which Goldmann III4e stimuli randomly moved along 16 vectors at a constant angular velocity of 5 deg/s. Results Glaucomatous peripheral visual field defects were seen in 18% of the eyes with a normal central visual field. In addition, 86% of glaucoma patients with moderate-to-severe central visual field defects had corresponding peripheral visual field defects in the form of localized or diffuse depression of the isopters. Furthermore, a moderate correlation was found between the central and peripheral visual fields. The median test duration was 71 s for the peripheral test and 803 s for the central test (p < 0.001). Conclusions Our study demonstrated the diversity of glaucomatous visual field defects, as well as the possibility of losing the clinically valuable information due to focusing on the central visual field test alone. The peripheral kinetic perimetry is clinically feasible to complement the central static perimetry for a comprehensive assessment of visual function in glaucoma patients.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The Far Nasal Part of the Field of Vision – Part II – Contribution to the Timely Diagnosis of Glaucoma;Czech and Slovak Ophthalmology;2023-11-20

2. Kinetic Perimetry on Virtual Reality Headset;IEEE Transactions on Biomedical Circuits and Systems;2023-06

3. Detecting disease progression in mild, moderate and severe glaucoma;Current Opinion in Ophthalmology;2022-11-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3