Author:
Lin Ke,Hu Zhixiang,Lin Zhong,Chen Tianyu,Tang Yongping,Wu Ronghan
Abstract
Abstract
Background
To report a new technique for iris capture of the posterior chamber intraocular lens (IOL) implanted in patients with a posterior capsule defect.
Methods
In this retrospective case series, a rectangular loop ciliary body suture technique was performed to rectify iris capture. The suture passes between the IOL and iris in a direction perpendicular to the iris edge capturing the IOL.
Results
A total of three IOLs with iris capture underwent a rectangular loop suture technique. No recapture was observed postoperatively. In one case, large astigmatism appeared after the surgery but recovered at 1 month post operation. No further complications were found.
Conclusions
The rectangular loop suture technique is an effective, convenient, and minimally invasive method for iris capture of the IOL.
Publisher
Springer Science and Business Media LLC
Subject
Ophthalmology,General Medicine
Reference16 articles.
1. Grehn F, Sundmacher R. Fixation of posterior chamber lenses by transscleral sutures: technique and preliminary results. Arch Ophthalmol. 1989;107(7):954–5.
2. Gabor SGB, Pavlidis MM. Sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg. 2007;33(11):1851–4.
3. Hu ZX, Lin HS, Ye L, Lin Z, Chen T, Lin K, Wu RH. Sutureless Intrascleral haptic-hook Lens implantation using 25-gauge trocars. J Ophthalmol. 2018;2018:9250425.
4. Teichmann KD, Teichmann IA. The torque and tilt gamble. J Cataract Refract Surg. 1997;23(3):413–8.
5. Cho BJ, Yu HG. Surgical outcomes according to vitreous management after scleral fixation of posterior chamber intraocular lenses. Retina (Philadelphia, Pa). 2014;34(10):1977–84.