One year outcomes after small incision lenticule extraction ReLEX in the correction of myopia and myopic astigmatism

Author:

Nicula Cristina Ariadna,Nicula Dorin,Bolboacă Sorana D.,Bulboacă Adriana Elena

Abstract

Abstract Purpose To report the visual and refractive outcomes of small incision lenticule extraction ReLEX (SMILE) technique using VisuMax femtosecond laser in myopia and myopic astigmatism patients. Material and methods A non-randomized clinical study has been conducted on patients with myopia and myopic astigmatism who underwent ReLEX SMILE technique, using the Zeiss VisuMax Laser system (Carl Zeiss Meditec AG, Jena, Germany) at Oculens Clinic, Cluj-Napoca, Romania. Patients older than 18 years, with ocular astigmatism up to -5 diopters (D), spherical equivalent up to -10.00 D, corrected distance visual acuity (CDVA) of 0.3 or better before the surgery, stable refraction for one year, and with a minimum calculated post operator residual stromal bed of 250μ were included in the study. Results The study involved a total of 25 myopic eyes (median of sphere diopters equal with -4D) and 67 myopic astigmatic eyes (median of cylinder diopters equal with -1.5 D). The mean refractive spherical equivalent (MRSE) on patients with myopic eyes reduced from -4.25D (median) to -0.5D at one month follow-up, -0.25 D at 6 and 12 months. The mean refractive spherical equivalent (MRSE) on patients with astigmatic myopic eyes reduced from-6.25 D to -0.67 D at one month, -0.62 D at six and twelve months. The value of sphere decreased postoperatively on myopic eyes with a median of -0.25D at one, six and twelve months. The value of cylinder decreased postoperatively on myopic astigmatic eyes with a median of -0.50 D at one month, -0.25 D at six months and -0.50 D at 12 months. At 6 and 12 months, 20 (80.0%) of myopic eyes were maintained within ±0.5 D and 22 (88.0%) with ±1D. On both groups (myopic eyes and myopic astigmatic eyes), statistically significant differences were observed when the keratometric baseline values were compared to each follow-up (P-values < 0.0001), without any significant differences between follow-ups (P-values>0.15). At 1-month follow-up, uncorrected distance visual acuity (UDVA) was better than or equal to 0.5 in 88.0% of myopic eyes and 82.1% of myopic astigmatic eyes. UDVA remained stable in all cases of myopic eyes at six months and the percentage increased at 92.0% in myopic eyes. UDVA slightly increased at 6-months (85.1%) and remained at the same value at 12-months in myopic astigmatism eyes. Conclusions SMILE proved an effective and safe refractive corneal procedure and provided a predictable and stable correction of myopia and myopic astigmatism. SMILE technique demonstrated very good outcomes in terms of keratometric, cylinder, spherical measurements.

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3