Continuous ab interno repairing of traumatic cyclodialysis cleft using a 30-gauge needle in severe ocular trauma: a clinical observation

Author:

Li HaiboORCID,Cai Jinhong,Li Xiaofeng

Abstract

Abstract Background To investigate the efficacy and safety of continuous ab interno repairing of traumatic cyclodialysis cleft in severe ocular trauma using a 30-gauge (G) needle. Methods Fifteen patients (15 eyes) with traumatic cyclodialysis cleft admitted to the ocular trauma department of our hospital from July 2014 to December 2018 were included in this study. After the bulbar conjunctiva corresponding to the ciliary body was incised along the corneal limbus, an incision was made along the corneal limbus on the opposite side. A 30G needle with a 10–0 suture entered the anterior chamber from the incision and passed through the ciliary body with clefts and the sclera to fixate the ciliary body on the sclera wall with continuous mattress suture. The best corrected visual acuity (BCVA) and intraocular pressure (IOP) were observed preoperatively and postoperatively. In vivo ultrasound biomicroscopy (UBM) was performed to observe closure of cyclodialysis cleft before and after surgery. Results Fifteen patients successfully underwent continuous mattress suture for repair of cyclodialysis cleft. No bleeding and suture breakage were reported during surgery. After surgery, the UBM during follow-up showed satisfactory closure of the cyclodialysis cleft. The BCVA and IOP were improved to different degrees. The difference between the preoperative IOP and the postoperative IOP (1 week) was statistically significant (preoperative: 6.49 ± 0.98 mmHg, postoperative: 16.17 ± 4.65 mmHg, t = − 8.43, P < 0.05), and the difference between the preoperative IOP and the postoperative IOP (1 month) was also statistically significant (preoperative: 6.49 ± 0.98 mmHg, postoperative: 14.63 ± 3.63 mmHg, t = − 8.38, P < 0.05). Duration of outpatient follow-up was 3 to 12 months. No complications, including exposed knots, loose sutures, decompensation of corneal endothelium, sympathetic ophthalmia, endophthalmitis and choroidal detachment, were reported. Conclusion Continuous ab interno repairing of traumatic cyclodialysis cleft in severe ocular trauma using a 30G needle is a safe and effective procedure with simple operation, little tissue damage and few complications.

Funder

the Science and Technology project of Xiamen Science and Technology Bureau

Scientific research project on health and family planning for youth in fujian province

Fujian provincial key talents training program for health and family planning

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3