Abstract
Abstract
Background
Equine small intestinal resection and anastomosis is a procedure where optimizing speed, without compromising integrity, is advantageous. There are a range of different needle holders available, but little is published on the impact surgical instrumentation has on surgical technique in veterinary medicine.
The objectives of this study were to investigate if the needle holder type influences the anastomosis construction time, the anastomosis bursting pressure and whether the bursting pressure is influenced by the anastomosis construction time.
Single layer end-to-end jejunojejunal anastomoses were performed on jejunal segments harvested from equine cadavers. These segments were randomly allocated to four groups. Three groups based on the needle holder type that was used: 16.5 cm Frimand (Group 1), 16 cm Mayo-Hegar (Group 2) or 20.5 cm Mayo-Hegar (Group 3) needle holders. One (Group 4) as control without anastomoses. Anastomosis construction time was recorded. Bursting pressure was determined by pumping green coloured fluid progressively into the lumen whilst recording intraluminal pressures. Maximum pressure reached prior to failure was recorded as bursting pressure. Construction times and bursting pressures were compared between needle holder, and the correlation between bursting pressure and construction time was estimated.
Results
Construction times were not statistically different between groups (P = 0.784). Segments from Group 2 and Group 3 burst at a statistically significantly lower pressure than those from Group 4; P = 0.031 and P = 0.001 respectively. Group 4 and Group 1 were not different (P = 0.125). The mean bursting pressure was highest in Group 4 (189 ± 61.9 mmHg), followed by Group 1 (166 ± 31 mmHg) and Group 2 (156 ± 42 mmHg), with Group 3 (139 ± 34 mmHg) having the lowest mean bursting pressure. Anastomosis construction time and bursting pressure were not correlated (P = 0.792).
Conclusions
The tested needle holders had a significant effect on bursting pressure, but not on anastomosis construction time. In an experimental setting, the Frimand needle holder produced anastomoses with higher bursting pressures. Further studies are required to determine clinical implications.
Publisher
Springer Science and Business Media LLC
Subject
General Veterinary,General Medicine
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献